5. CONTROL SYSTEM
MAIN FUNCTIONS
Outdoor unit low noise operation
Users can choose from 4 low
●
noise levels, depending on the
installation environment.
100%
58dB
0
0
Heat load
Air
conditioning
load factor
Low noise operation
Operating
sound
Capacity
Down
(time)
Minimum heat (All) operation
While this function is selected, all indoor
●
units start the minimum heat operation
when all the indoor units are stopped by
operation of the [On/Off button].
When the room temperature is higher than
●
50°F (10°C), MIN. HEAT operation starts
and maintains the room temperature at
50°F (10°C) when the temperature drops
below 50°F (10°C).
When “MIN, HEAT operation stops, the
●
room set temperature quickly returns to the
preset temperature.
50
°F
70
°F
Indoor unit
operation
START
“All MIN. HEAT”
operation
All indoor units
ON
OFF
Economy (All) operation
Example : Cooling operation
If all the indoor and outdoor units are
●
changed to economy mode, this can save
more energy than setting of each indoor
unit individually.
Economy operation is energy saving, as
●
the set temperature of indoor unit is shifted
by 2°F (1°C) and the maximum electric
value of the outdoor unit is suppressed.
T
emp.
Economy operation
Shift
setting
temp
Control maxmum current
Nomal operation
Time
Set temperature
Schedule timer
Example
Operation setting can be changed
●
4 times in each day of a week, and
2types of the schedule can be set
to suit users' preference.
y
a
d
n
u
S
~
y
a
d
r
u
t
a
S
y
a
d
i
r
F
~
y
a
d
n
o
M
AM7
AM7
AM7
PM12 PM1
PM1
PM6
PM11
PM11
AM8
PM12
PM1
PM6
PM10
PM5
PM11
Time
T
emp.
T
emp.
T
emp.
T
emp.
Time
Time
Time
Summer
season
pattern
Winter
season
pattern
Cool
Cool
Cool
Cool
Cool
Cool
Heat
Heat
Heat
Heat
Heat
Heat
Prohibited Settings
The remote controller operation of all indoor units comes with a lock function to prevent
unapproved operations in the various rooms. The central remote controller also has a key lock
function to prevent children from playing with it, etc
- (05 - 08) -
CO
NT
RO
L
SY
S
T
E
M
CO
NT
RO
L
SY
S
T
E
M
Содержание ARU12RLF
Страница 1: ...VD014E 06 FUJITSU GENERAL LIMITED DESIGN TECHNICAL MANUAL Hybrid Flex Inverter System DTR_BMU001E_05 ...
Страница 3: ...1 GENERAL INFORMATION DTR_BMU001E_03 CHAPTER01 2010 08 25 Hybrid Flex Inverter System ...
Страница 18: ...2 MODEL SELECTION DTR_BMU001E_04 CHAPTER02 2010 10 04 Hybrid Flex Inverter System ...
Страница 38: ...3 OUTDOOR UNIT BRANCH BOX Hybrid Flex Inverter System DTR_BMU001E_04 CHAPTER03 2010 10 04 ...
Страница 58: ...4 INDOOR UNITS Hybrid Flex Inverter System DTR_BMU001E_05 CHAPTER04 2010 11 12 ...
Страница 82: ...4 INDOOR UNITS SLIM DUCT TYPE 5 2 MODELS ARU9RLF ARU12RLF ARU18RLF ARU24RLF 04 22 INDOOR UNITS INDOOR UNITS ...
Страница 83: ...4 INDOOR UNITS COMPACT WALL MOUNTED TYPE 5 3 MODELS AS U7RLF ASU9RLF ASU12RLF 04 23 INDOOR UNITS INDOOR UNITS ...
Страница 84: ...4 INDOOR UNITS WALL MOUNTED TYPE 5 4 MODELS AS U18RLF ASU24RLF 04 24 INDOOR UNITS INDOOR UNITS ...
Страница 116: ...5 CONTROL SYSTEM DTR_BMU001E_04 CHAPTER05 2010 10 04 Hybrid Flex Inverter System ...
Страница 152: ...6 SYSTEM DESIGN DTR_BMU001E_04 CHAPTER06 2010 10 04 Hybrid Flex Inverter System ...
Страница 287: ...7 OPTIONAL PARTS Hybrid Flex Inverter System DTR_BMU001E_03 CHAPTER07 2010 08 25 ...
Страница 288: ...CONTENTS 7 OPTIONAL PARTS 1 SEPARATION TUBE 07 01 2 BRANCH BOX 07 02 3 CONTROLLER 07 04 4 OTHERS 07 05 ...