5. CONTROL SYSTEM
SYSTEM CONFIGURATION EXAMPLES
1-3.
INDIVIDUAL CONTROL
Wired Remote Controller
Wireless Remote Controller
Simple Remote Controller
Central Remote Controller
Wired, simple, and wireless remote controllers can
●
be used jointly.
Two remote controllers can be connected with single
●
indoor unit.
Wired, simple, and wireless remote controllers can
●
be used jointly.
Up to 8 indoor units can be controlled with one
●
central remote controller.
The central remote controller can be used
●
simultaneously with wired, simple, and wireless
remote controller.
Only one can be used for one system.
●
Enables easy control of basic functions by the hotel
●
or office guest.
Two remote controller can be connected with single
●
indoor unit.
CENTRAL CONTROL
Wired Remote Controller
Outdoor
unit
Branch box
(Primary)
Branch box
(Secondary 1)
Branch box
(Secondary 2)
Outdoor
unit
Branch box
(Primary)
Branch box
(Secondary 1)
Branch box
(Secondary 2)
Simple & Wired Remote Controller
Outdoor
unit
Branch box
(Primary)
Branch box
(Secondary 1)
Branch box
(Secondary 2)
Wireless & Wired Remote Controller
Outdoor
unit
Branch box
(Primary)
Branch box
(Secondary 1)
Branch box
(Secondary 2)
Central Remote
Controller
- (05 - 03) -
CO
NT
RO
L
SY
S
T
E
M
CO
NT
RO
L
SY
S
T
E
M
Содержание ARU12RLF
Страница 1: ...VD014E 06 FUJITSU GENERAL LIMITED DESIGN TECHNICAL MANUAL Hybrid Flex Inverter System DTR_BMU001E_05 ...
Страница 3: ...1 GENERAL INFORMATION DTR_BMU001E_03 CHAPTER01 2010 08 25 Hybrid Flex Inverter System ...
Страница 18: ...2 MODEL SELECTION DTR_BMU001E_04 CHAPTER02 2010 10 04 Hybrid Flex Inverter System ...
Страница 38: ...3 OUTDOOR UNIT BRANCH BOX Hybrid Flex Inverter System DTR_BMU001E_04 CHAPTER03 2010 10 04 ...
Страница 58: ...4 INDOOR UNITS Hybrid Flex Inverter System DTR_BMU001E_05 CHAPTER04 2010 11 12 ...
Страница 82: ...4 INDOOR UNITS SLIM DUCT TYPE 5 2 MODELS ARU9RLF ARU12RLF ARU18RLF ARU24RLF 04 22 INDOOR UNITS INDOOR UNITS ...
Страница 83: ...4 INDOOR UNITS COMPACT WALL MOUNTED TYPE 5 3 MODELS AS U7RLF ASU9RLF ASU12RLF 04 23 INDOOR UNITS INDOOR UNITS ...
Страница 84: ...4 INDOOR UNITS WALL MOUNTED TYPE 5 4 MODELS AS U18RLF ASU24RLF 04 24 INDOOR UNITS INDOOR UNITS ...
Страница 116: ...5 CONTROL SYSTEM DTR_BMU001E_04 CHAPTER05 2010 10 04 Hybrid Flex Inverter System ...
Страница 152: ...6 SYSTEM DESIGN DTR_BMU001E_04 CHAPTER06 2010 10 04 Hybrid Flex Inverter System ...
Страница 287: ...7 OPTIONAL PARTS Hybrid Flex Inverter System DTR_BMU001E_03 CHAPTER07 2010 08 25 ...
Страница 288: ...CONTENTS 7 OPTIONAL PARTS 1 SEPARATION TUBE 07 01 2 BRANCH BOX 07 02 3 CONTROLLER 07 04 4 OTHERS 07 05 ...