5. CONTROL SYSTEM
WIRED REMOTE CONTROLLER
2-2.
MODEL : UTY - RNNUM
FEATURES
Powerful features and compact size
Thermo
sensor
Individual
control
Weekly
timer
Setback
timer
Wired
remote
controller
Sensor part
Thermo sensor
display
Control part for
changing the
thermo sensor
Accurate and comfortable
Indoor temperature can be detected accurately by the inclusion of a
thermo sensor in the body of the wired controller.
Our system can correspond to various scenes.
This wired remote controller and the optional remote sensor allows
flexibility in sensor location, and suitable for all requirements.
Built-in timers
Weekly timer
Setback timer
Possible to set ON/OFF time to operate twice each day of the
week.
Possible to set temperature for two time spans and for each
day of the week.
At "Weekly timer" + "Set back timer" setup
76°F (24°C)
0
3
6
9
12
15
18
21
O'clock
12
3
6
9
12
3
6
9
time
AM
PM
Easy-to-understand time bar display
Example : setup screen
(Set to Wednesday: 8:00 to 20:00.)
Screen
after setup
84°F (28°C)
0
3
6
9
12
15
18
21
O'clock
12
3
6
9
12
3
6
9
time
AM
PM
Example : setup screen
(Set from Sunday to Saturday: 12:00 to 15:00, 28 °C.)
76°F
84°F
76°F
0
3
6
9
12
15
18
21
O'clock
12
3
6
9
12
3
6
9
time
AM
PM
76°F (24°C)
84°F (28°C)
24°C
28°C
24°C
Easy-to-understand operation
[Variable timer control]
The operation/display sections are zoned according
to time and operation, enabling variable programming
to match application.
Simple installation
Components are compatible with standard switch
boxes. Flat back surface allows equipment to be
installed wherever it is needed.
Timer
area
Operation
area
European
switch box
JIS box
Various timer setup (ON / OFF / WEEKLY) are possible.
●
Equipped with weekly timer as standard function.
●
(Start / Stop function is twice per day for a week)
When setting up a timer, start / stop and a temperature setup can
●
be changed.
When a failure occurs,the error code is displayed.
●
Error history.(Last 16 error codes can be accessed.)
●
The room temperature can be controlled by being detective the
●
temperature accurately with Built-in thermo sensor.
- (05 - 13) -
CO
NT
RO
L
SY
S
T
E
M
CO
NT
RO
L
SY
S
T
E
M
Содержание ARU12RLF
Страница 1: ...VD014E 06 FUJITSU GENERAL LIMITED DESIGN TECHNICAL MANUAL Hybrid Flex Inverter System DTR_BMU001E_05 ...
Страница 3: ...1 GENERAL INFORMATION DTR_BMU001E_03 CHAPTER01 2010 08 25 Hybrid Flex Inverter System ...
Страница 18: ...2 MODEL SELECTION DTR_BMU001E_04 CHAPTER02 2010 10 04 Hybrid Flex Inverter System ...
Страница 38: ...3 OUTDOOR UNIT BRANCH BOX Hybrid Flex Inverter System DTR_BMU001E_04 CHAPTER03 2010 10 04 ...
Страница 58: ...4 INDOOR UNITS Hybrid Flex Inverter System DTR_BMU001E_05 CHAPTER04 2010 11 12 ...
Страница 82: ...4 INDOOR UNITS SLIM DUCT TYPE 5 2 MODELS ARU9RLF ARU12RLF ARU18RLF ARU24RLF 04 22 INDOOR UNITS INDOOR UNITS ...
Страница 83: ...4 INDOOR UNITS COMPACT WALL MOUNTED TYPE 5 3 MODELS AS U7RLF ASU9RLF ASU12RLF 04 23 INDOOR UNITS INDOOR UNITS ...
Страница 84: ...4 INDOOR UNITS WALL MOUNTED TYPE 5 4 MODELS AS U18RLF ASU24RLF 04 24 INDOOR UNITS INDOOR UNITS ...
Страница 116: ...5 CONTROL SYSTEM DTR_BMU001E_04 CHAPTER05 2010 10 04 Hybrid Flex Inverter System ...
Страница 152: ...6 SYSTEM DESIGN DTR_BMU001E_04 CHAPTER06 2010 10 04 Hybrid Flex Inverter System ...
Страница 287: ...7 OPTIONAL PARTS Hybrid Flex Inverter System DTR_BMU001E_03 CHAPTER07 2010 08 25 ...
Страница 288: ...CONTENTS 7 OPTIONAL PARTS 1 SEPARATION TUBE 07 01 2 BRANCH BOX 07 02 3 CONTROLLER 07 04 4 OTHERS 07 05 ...