2.3. For authorized service personnel only.

 WARNING

For the air conditioner to operate satisfactorily, install it as outlined in this installation 
manual.

Connect the indoor unit and outdoor unit with the air conditioner piping and cables 
available from your local distributor. This installation manual describes the correct con-
nections using the installation set available from your local distributor.

Installation work must be performed in accordance with national wiring standards by 
authorized personnel only.

Do not turn on the power until all installation work is complete.

 CAUTION

This installation manual describes how to install the indoor unit only. 
To install the outdoor unit, refer to the installation manual included with the outdoor unit.

•  Be careful not to scratch the air conditioner when handling it.
•  After installation, explain correct operation to the customer, using the operating manual.

2.4. Accessories

The following installation accessories are supplied. Use them as required.

Name and Shape

Q’ty

Name and Shape

Q’ty

Operating Manual

1

Remote controller holder

1

Installation Manual (This 

manual)

1

Cloth tape

1

Wall hook bracket

1

Tapping screw

(M4 × 25 mm)

8

Remote controller

1

Tapping screw

(M3 × 12 mm)

2

Battery

2

Air cleaning filter

2

The following items are necessary to install this air conditioner. (The items are not includ-
ed with the air conditioner and must be purchased separately.)

Name Q’ty

Name Q’ty

Connection pipe assembly

1

Wall cap

1

Connection cable (4-conductor)

1

Saddle

1 set

Wall pipe

1

Drain hose

1

Decorative tape

1

Tapping screws

1 set

Vinyl tape

1

Sealant

1

2.5. Optional parts

Refer to each installation manual for the method of installing optional parts.

Parts name

Model No.

Application

Wired Remote Controller *

UTY-RNN

¾

M

For air conditioner operation

Simple Remote Controller *

UTY-RSN

¾

M

For air conditioner operation

External connect kit *

UTY-XWZX

For control input/output port

Communication kit

UTY-XCBXZ1

For the installation of optional parts

* Optional communication kit is necessary for the installation.

3. GENERAL

This INSTALLATION MANUAL brie

À

 y outlines where and how to install the air conditioning system. 

Please read over the entire set of instructions for the indoor and outdoor units and make sure all 
accessory parts listed are with the system before beginning.

3.1. Type of copper pipe and insulation material

 CAUTION

Refer to the installation manual for the outdoor unit for description of allowable pipe length 
and height difference.

Diameter

Liquid pipe

Gas pipe

6.35 mm (1/4 in.)

12.7 mm (1/2 in.)

 CAUTION

Install heat insulation around both the gas and liquid pipes. Failure to do so may 
cause water leaks.
Use heat insulation with heat resistance above 120 °C. Reverse cycle model only)
In addition, if the humidity level at the installation location of the refrigerant piping is 
expected to exceed 70%, install heat insulation around the refrigerant piping. If the 
expected humidity level is 70-80%, use heat insulation that is 15 mm or thicker and if 
the expected humidity exceeds 80%, use heat insulation that is 20 mm or thicker.
If heat insulation is used that is not as thick as speci

¿

 ed, condensation may form on the surface 

of the insulation.
In addition, use heat insulation with heat conductivity of 0.045 W/(m•K) or less 20 °C.

3.2. Additional materials required for installation

A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire (See your local electrical codes.)
C. Putty
D. Refrigeration lubricant

E. Clamps or saddles to secure refrigerant piping

4. ELECTRICAL REQUIREMENT

The indoor unit is powered from the outdoor unit. Do not power indoor unit from separate 
power source.

 WARNING

Refer to local codes for acceptable cable type.

Cable

Cable size

Remarks

Connection cable

Type 60245 IEC 57

(1.5 mm

2

 )

3 cable + Ground, 1 Ø 230 V

Max. Cable Length: Limit voltage drop to less than 2%. Increase cable gauge if voltage 
drop is 2% or more.

9332279085-02_IM.indb   2

2011-9-26   13:31:05

Содержание AOYG12LEC

Страница 1: ...Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CO...

Страница 2: ...After turning off the power always wait 5 minutes before touching electrical components This unit contains no user serviceable parts Always consult authorized service person nel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as...

Страница 3: ...peration External connect kit UTY XWZX For control input output port Communication kit UTY XCBXZ1 For the installation of optional parts Optional communication kit is necessary for the installation 3 GENERAL This INSTALLATION MANUAL brieÀy outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and outdoor units and make sure all...

Страница 4: ... degrade the quality of the preserved or stored objects Do not install where there is the danger of combustible gas leakage Do not install the unit near a source of heat steam or Àammable gas Install the unit where drainage does not cause any trouble Install the indoor unit outdoor unit power supply cable transmission cable and remote control cable at least 1 m away from a television or radio rece...

Страница 5: ... taken to prevent drain water freezing Under low temperature environment when outdoor temperature under 0 C after cooling operation is executed water in the drain hose could be frozen Once drain water is frozen the drain hose will be blocked and water leakage may result at the indoor unit Installation method of Drain cap Use a hexagonal wrench 4 mm at opposite side to insert the drain cap till the...

Страница 6: ...with R410A Àare tools to achieve the speci ed Àaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 6 6 2 Bending pipes If pipes are shaped by hand be careful not to collapse them Do not bend the pipes in an angle more than 90 When pipes are repeatedly ...

Страница 7: ...th a knife etc 1 Use crimp type terminals with insulating sleeves as shown in the gure below to con nect to the terminal block 2 Securely clamp the crimp type terminals to the wires using an appropriate tool so that the wires do not come loose Strip 10 mm Crimp type terminal Sleeve 3 Use the speci ed wires connect them securely and fasten them so that there is no stress placed on the terminals 4 U...

Страница 8: ...nd bottom piping overlap the connection pipe heat insulation and indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap For left and left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with and vinyl tape so that there is no gap For left and left rear piping wrap the area which accommodates the rear p...

Страница 9: ...not be changed if invalid numbers or setting values are selected Refer to the installation manual enclosed with the remote control unit when the wired remote control unit option is used Entering the Function Setting Mode While pressing the POWERFUL button and SET TEMP simultaneously press the RESET button to enter the function setting mode STEP 1 Selecting the Remote Controller Signal Code Use the...

Страница 10: ...ate by the control unit or external input device Indoor room temperature sensor switching function Only for Wired remote controller The following settings are needed when using the Wired remote controller temperature sensor Ƈ Factory setting Setting Description Function Number Setting Value Ƈ No 42 00 Yes 01 If setting value is 00 Room temperature is controlled by the indoor unit temperature senso...

Страница 11: ... terminal L error Ɣ 6 Ɣ 10 Display PCB microcomputers communication error Ɣ 7 Ɣ 1 Discharge temp sensor error Ɣ 7 Ɣ 2 Compressor temp sensor error Ɣ 7 Ɣ 3 Outdoor unit Heat Ex liquid temp sensor error Ɣ 7 Ɣ 4 Outdoor temp sensor error Ɣ 7 Ɣ 5 Suction Gas temp sensor error Ɣ 7 Ɣ 6 2 way valve temp sensor error 3 way valve temp sensor error Ɣ 7 Ɣ 7 Heat sink temp sensor error Ɣ 8 Ɣ 2 Sub cool Heat E...

Страница 12: ... 7 9 3 Rimozione del pannello frontale 1 Rimuovere la griglia di aspirazione consultare le istruzioni per la rimozione della griglia di aspirazione 2 Rimuovere la copertura del cavo 3 Rimuovere le 3 viti ...

Страница 13: ... INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION...

Страница 14: ...the composition of the gas and liquid phases And always charge from the liquid phase where refrigerant composition is stable 2 2 Special tools for R410A Tool name Contents of change Gauge manifold Pressure is high and cannot be measured with a conven tional R22 gauge To prevent erroneous mixing of other refrigerants the diameter of each port has been changed It is recommended the gauge with seals ...

Страница 15: ...ight of the outdoor units and install positively so that the units will not topple or fall CAUTION Do not install where there is the danger of combustible gas leakage Do not install near heat sources In places where the outdoor temperature drops to 0 ÛC or lower the drain water may freeze and may stop up the drain or cause other outdoor unit trouble Therefore take measures so that the drain water ...

Страница 16: ... Bend the pipe with a radius of curvature of 70mm or over 3 If the copper pipe is bend the pipe or pulled to often it will become stiff Do not bend the pipes more than three times at one place Tighten with two wrenches Torque wrench Wrench xed Flare nut Indoor unit pipe Connection pipe To prevent gas leakage coat the Àare surface with refrigerator oil Table 1 Flare nut size and tightening torque F...

Страница 17: ... TIMER indicator lamp of the indoor unit will simultaneously Àash slowly OUTDOOR UNIT 1 Is there any abnormal noise and vibration during operation 2 Will noise wind or drain water from the unit disturb the neighbors 3 Is there any gas leakage 6 PUMP DOWN 6 1 Pump down PUMP DOWN OPERATION FORCED COOLING OPERATION To avoid discharging refrigerant into the atmosphere at the time of relocation or disp...

Отзывы: