5.  SELECTING THE MOUNTING POSITION

Decide the mounting position with the customer as follows:

5.1. Indoor unit

(1)  Install the indoor unit level on a strong wall which is not subject to vibration.
(2)  The inlet and outlet ports should not be obstructed : the air should be able to blow all 

over the room.

(3)

Install the unit a dedicated electrical branch circuit.

(4)

Do not install the unit where it will be exposed to direct sunlight.

(5)

Install the unit where connection to the outdoor unit is easy.

(6)  Install the unit where the drain pipe can be easily installed.
(7)  Take servicing, etc. into consideration and leave the spaces shown in [6.1. Installation 

dimensions]. Also install the unit where the 

¿

 lter can be removed.

Correct initial installation location is important because it is dif

¿

 cult to move unit after it is 

installed.

 WARNING

Select installation locations that can properly support the weight of the indoor. Install the units securely 
so that they do not topple or fall.

 CAUTION

Do not install the unit in the following areas:
• Area with high salt content, such as at the seaside. It will deteriorate metal parts, causing the parts 

to fail or the unit to leak water.

• Area

¿

 lled with mineral oil or containing a large amount of splashed oil or steam, such as a 

kitchen. 
It will deteriorate plastic parts, causing the parts to fail or the unit to leak water.

• Area that generates substances that adversely affect the equipment, such as sulfuric gas, chlorine 

gas, acid, or alkali. 
It will cause the copper pipes and brazed joints to corrode, which can cause refrigerant leakage.

• Area that can cause combustible gas to leak, contains suspended carbon 

¿

 bers or 

À

 ammable 

dust, or volatile in

À

 ammables such as paint thinner or gasoline.

• If gas leaks and settles around the unit, it can cause a 

¿

 re.

• Area where animals may urinate on the unit or ammonia may be generated.

Do not use the unit for special purposes, such as storing food, raising animals, growing 
plants, or preserving precision devices or art objects.
It can degrade the quality of the preserved or stored objects.

Do not install where there is the danger of combustible gas leakage.

Do not install the unit near a source of heat, steam, or 

À

 ammable gas.

Install the unit where drainage does not cause any trouble.

Install the indoor unit, outdoor unit, power supply cable, transmission cable, and remote 
control cable at least 1 m away from a television or radio receivers. The purpose of this 
is to prevent TV reception interference or radio noise.
(Even if they are installed more than 1 m apart, you could still receive noise under some 
signal conditions.)

If children under 10 years old may approach the unit, take preventive measures so that 
they cannot reach the unit.

Install the indoor unit on the wall where the height from the 

À

 oors more than 1800 mm.

6. INSTALLATION WORK

6.1. Installation dimensions

70 mm or over 

1.5 m or over 

Remote
controller

Remote controller holder

Tapping screw (small)

1.8 m 
or over

(Wallcap)

63 mm or over

Wall hook 
bracket

100 mm or over

6.2. Indoor unit piping direction

The piping can be connected in the 6 directions indicated in the following.

When the piping is connected in direction 

2

 , 

3

 , 

4

 or 

5

 , cut along the piping groove in 

the side of the front cover with a hacksaw.

(Rear)

2

Right
outlet

5

Left
outlet

6

Left rear 
outlet

3

Bottom outlet

1

Rear outlet

4

Left bottom outlet

6.3. Cutting the hole in the wall for the connecting piping

(1)  Cut a 65 mm diameter hole in the wall at the position shown in the following.
(2)  Cut the hole so that the outside end is lower (5 to 10 mm) than the inside end.
(3)  Always align the center of the wall hole. If misaligned, water leakage will occur.
(4)

Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap with 
vinyl tape, and stick the pipe through the hole.

(5)  For left piping and right piping, cut the hole a little lower so that drain water will 

À

 ow 

freely. 

Wall

Fasten with 
vinyl tape

65 mm dia. hole

65 mm dia. hole

Wall hook bracket

Center mark

Center mark

Wall cap*

Wall pipe*

(Inside)

(Outside)

5 to 10 mm low

 WARNING

If the wall pipe is not used, the cable interconnecting the indoor unit(s) and outdoor unit 
may touch metal and cause electric discharge.

*Field supplied

9332279085-02_IM.indb   3

2011-9-26   13:31:07

Содержание AOYG12LEC

Страница 1: ...Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CO...

Страница 2: ...After turning off the power always wait 5 minutes before touching electrical components This unit contains no user serviceable parts Always consult authorized service person nel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as...

Страница 3: ...peration External connect kit UTY XWZX For control input output port Communication kit UTY XCBXZ1 For the installation of optional parts Optional communication kit is necessary for the installation 3 GENERAL This INSTALLATION MANUAL brieÀy outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and outdoor units and make sure all...

Страница 4: ... degrade the quality of the preserved or stored objects Do not install where there is the danger of combustible gas leakage Do not install the unit near a source of heat steam or Àammable gas Install the unit where drainage does not cause any trouble Install the indoor unit outdoor unit power supply cable transmission cable and remote control cable at least 1 m away from a television or radio rece...

Страница 5: ... taken to prevent drain water freezing Under low temperature environment when outdoor temperature under 0 C after cooling operation is executed water in the drain hose could be frozen Once drain water is frozen the drain hose will be blocked and water leakage may result at the indoor unit Installation method of Drain cap Use a hexagonal wrench 4 mm at opposite side to insert the drain cap till the...

Страница 6: ...with R410A Àare tools to achieve the speci ed Àaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 6 6 2 Bending pipes If pipes are shaped by hand be careful not to collapse them Do not bend the pipes in an angle more than 90 When pipes are repeatedly ...

Страница 7: ...th a knife etc 1 Use crimp type terminals with insulating sleeves as shown in the gure below to con nect to the terminal block 2 Securely clamp the crimp type terminals to the wires using an appropriate tool so that the wires do not come loose Strip 10 mm Crimp type terminal Sleeve 3 Use the speci ed wires connect them securely and fasten them so that there is no stress placed on the terminals 4 U...

Страница 8: ...nd bottom piping overlap the connection pipe heat insulation and indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap For left and left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with and vinyl tape so that there is no gap For left and left rear piping wrap the area which accommodates the rear p...

Страница 9: ...not be changed if invalid numbers or setting values are selected Refer to the installation manual enclosed with the remote control unit when the wired remote control unit option is used Entering the Function Setting Mode While pressing the POWERFUL button and SET TEMP simultaneously press the RESET button to enter the function setting mode STEP 1 Selecting the Remote Controller Signal Code Use the...

Страница 10: ...ate by the control unit or external input device Indoor room temperature sensor switching function Only for Wired remote controller The following settings are needed when using the Wired remote controller temperature sensor Ƈ Factory setting Setting Description Function Number Setting Value Ƈ No 42 00 Yes 01 If setting value is 00 Room temperature is controlled by the indoor unit temperature senso...

Страница 11: ... terminal L error Ɣ 6 Ɣ 10 Display PCB microcomputers communication error Ɣ 7 Ɣ 1 Discharge temp sensor error Ɣ 7 Ɣ 2 Compressor temp sensor error Ɣ 7 Ɣ 3 Outdoor unit Heat Ex liquid temp sensor error Ɣ 7 Ɣ 4 Outdoor temp sensor error Ɣ 7 Ɣ 5 Suction Gas temp sensor error Ɣ 7 Ɣ 6 2 way valve temp sensor error 3 way valve temp sensor error Ɣ 7 Ɣ 7 Heat sink temp sensor error Ɣ 8 Ɣ 2 Sub cool Heat E...

Страница 12: ... 7 9 3 Rimozione del pannello frontale 1 Rimuovere la griglia di aspirazione consultare le istruzioni per la rimozione della griglia di aspirazione 2 Rimuovere la copertura del cavo 3 Rimuovere le 3 viti ...

Страница 13: ... INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION...

Страница 14: ...the composition of the gas and liquid phases And always charge from the liquid phase where refrigerant composition is stable 2 2 Special tools for R410A Tool name Contents of change Gauge manifold Pressure is high and cannot be measured with a conven tional R22 gauge To prevent erroneous mixing of other refrigerants the diameter of each port has been changed It is recommended the gauge with seals ...

Страница 15: ...ight of the outdoor units and install positively so that the units will not topple or fall CAUTION Do not install where there is the danger of combustible gas leakage Do not install near heat sources In places where the outdoor temperature drops to 0 ÛC or lower the drain water may freeze and may stop up the drain or cause other outdoor unit trouble Therefore take measures so that the drain water ...

Страница 16: ... Bend the pipe with a radius of curvature of 70mm or over 3 If the copper pipe is bend the pipe or pulled to often it will become stiff Do not bend the pipes more than three times at one place Tighten with two wrenches Torque wrench Wrench xed Flare nut Indoor unit pipe Connection pipe To prevent gas leakage coat the Àare surface with refrigerator oil Table 1 Flare nut size and tightening torque F...

Страница 17: ... TIMER indicator lamp of the indoor unit will simultaneously Àash slowly OUTDOOR UNIT 1 Is there any abnormal noise and vibration during operation 2 Will noise wind or drain water from the unit disturb the neighbors 3 Is there any gas leakage 6 PUMP DOWN 6 1 Pump down PUMP DOWN OPERATION FORCED COOLING OPERATION To avoid discharging refrigerant into the atmosphere at the time of relocation or disp...

Отзывы: