En-7

9.3. Front panel removal

 (1)  Remove intake grille (Reference the intake grille removal.)
 (2)  Remove wire cover.
 (3)  Remove 3 screws.

Screws (3 position)

Screws (Wire cover)

Wire cover

Wall hook bracket

Push the [

Ÿ

] marks.

 (4)  The front panel is pulled to the front, raising the upper surface, and a front panel is 

removed.

Front panel

9.4. Front panel installation

(1) First, 

¿

 t the lower part of the front panel, and insert top and bottom hooks. (3 top 

sides, 6 bottom sides, 2 center)

Indoor 
unit

Bottom holes 
(6 position)

Center hooks 
(2 position)

Top hooks 

(3 position)

Top holes (3 position)

Indoor unit

Front panel

Latchs (2 position)

Bottom hooks (6 position)

Front panel

(2)  Attach the 3 screws.

(3)  Attach the wire cover.

(4)  Attach the intake grille.

 CAUTION

Install the Front panel and Intake grille securely. If installation is imperfect, the Front 
panel or Intake grille may fall off and cause injury.

10. TEST  RUN

Check items

(1)  Is operation of each button on the remote control unit normal?
(2)  Does each lamp light normally?
(3) Do 

air 

À

 ow direction louvers operate normally?

(4)  Is the drain normal?
(5)  Do not have an abnormal noise and vibration during operation?

x

 

Do not operate the air conditioner in test run for a long time.

[Operation method]

x

  For the operation method, refer to the operating manual.

x

The outdoor unit, may not operate, depending on the room temperature. In this 
case, keep on pressing the MANUAL AUTO button of the indoor unit for more than 
10 seconds. The operation indicator lamp and timer indicator lamp will begin to 

À

 ash 

simultaneously during cooling test run. Then, heating test run will begin in about three 
minutes when HEAT is selected by the remote control operation. (Please follow the 
operating manual for remote control operation.)

8. FINISHING 

 (1)  Insulate between pipes.

•  Insulate suction and discharge pipes separately.
•  For rear, right, and bottom piping, overlap the connection pipe heat insulation and 

indoor unit pipe heat insulation and bind them with vinyl tape so that there is no 
gap.

•  For left and left rear piping, butt the connection pipe heat insulation and indoor unit 

pipe heat insulation together and bind them with and vinyl tape so that there is no 
gap.

•  For left and left rear piping, wrap the area which accommodates the rear piping 

housing section with cloth tape.

•  For left and left rear piping, bind the 

connection cable to the top of the pipe with 
vinyl tape.

•  For left and left rear piping, bundle the piping 

and drain hose together by wrapping them 
with cloth tape over the range within which 
they

¿

 t into the rear piping housing section.

 (2)  Temporarily fasten the connection cable 

along the connection pipe with vinyl tape. 
(Wrap to about 1/3 the width of the tape 
from the bottom of the pipe so that water 
does not enter.)

 (3)  Fasten the connection pipe to the outside 

wall with a saddle, etc.

 (4)  Fill the gap between the outside wall pipe 

hole and the pipe with sealer so that rain 
water and wind cannot blow in.

 (5)  Fasten the drain hose to the outside wall, etc.

Pipe

Saddle*

Outside wall cap*

Sealer putty*

(Outdoors)

Wall

Overlap the insulation

Vinyl tape

Wrap with cloth tape 

Cloth tape

Drain hose

Connection cable

Pipe

Drain hose

Check the following:

GOOD

Drain hose

Saddle

Lifted up

Wave

End in water

Drain hose

Connection pipe

Wall pipe

Connection cable

Left piping

For connection from the left rear

NO GOOD NO GOOD NO GOOD

Pipe

Connection pipe 
(heat insulation)

Indoor unit pipe
(heat insulation)

9.  FRONT PANEL REMOVAL AND INSTALLATION

9.1. Intake grill removal

 (1)  Open the intake grille.
 (2)  Pull down the knob.
 (3)  Lift the intake grille upward, until the axle at the top of the intake grille is removed.

9.2. Intake grill installation

 (1)  The 

¿

 xing axle of the intake grille is installed on the Panel.

 (2)  Lay down the intake grille.

Intake grille

Mounting shaft
Bearing

Front panel

Intake grille

Knob

*Field supplied

Bind the pipes together 
so that there is no gap.

9332279085-02_IM.indb   7

2011-9-26   13:31:11

Содержание AOYG12LEC

Страница 1: ...Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION MANUAL AIR CO...

Страница 2: ...After turning off the power always wait 5 minutes before touching electrical components This unit contains no user serviceable parts Always consult authorized service person nel to repairs When moving consult authorized service personnel for disconnection and installation of the unit 2 ABOUT THE UNIT 2 1 Precautions for using R410A refrigerant The basic installation work procedures are the same as...

Страница 3: ...peration External connect kit UTY XWZX For control input output port Communication kit UTY XCBXZ1 For the installation of optional parts Optional communication kit is necessary for the installation 3 GENERAL This INSTALLATION MANUAL brieÀy outlines where and how to install the air conditioning system Please read over the entire set of instructions for the indoor and outdoor units and make sure all...

Страница 4: ... degrade the quality of the preserved or stored objects Do not install where there is the danger of combustible gas leakage Do not install the unit near a source of heat steam or Àammable gas Install the unit where drainage does not cause any trouble Install the indoor unit outdoor unit power supply cable transmission cable and remote control cable at least 1 m away from a television or radio rece...

Страница 5: ... taken to prevent drain water freezing Under low temperature environment when outdoor temperature under 0 C after cooling operation is executed water in the drain hose could be frozen Once drain water is frozen the drain hose will be blocked and water leakage may result at the indoor unit Installation method of Drain cap Use a hexagonal wrench 4 mm at opposite side to insert the drain cap till the...

Страница 6: ...with R410A Àare tools to achieve the speci ed Àaring Use a thickness gauge to measure the dimension A Width across flats Pipe outside diameter mm in Width across flats of Flare nut mm 6 35 1 4 17 9 52 3 8 22 12 70 1 2 26 15 88 5 8 29 19 05 3 4 36 6 6 2 Bending pipes If pipes are shaped by hand be careful not to collapse them Do not bend the pipes in an angle more than 90 When pipes are repeatedly ...

Страница 7: ...th a knife etc 1 Use crimp type terminals with insulating sleeves as shown in the gure below to con nect to the terminal block 2 Securely clamp the crimp type terminals to the wires using an appropriate tool so that the wires do not come loose Strip 10 mm Crimp type terminal Sleeve 3 Use the speci ed wires connect them securely and fasten them so that there is no stress placed on the terminals 4 U...

Страница 8: ...nd bottom piping overlap the connection pipe heat insulation and indoor unit pipe heat insulation and bind them with vinyl tape so that there is no gap For left and left rear piping butt the connection pipe heat insulation and indoor unit pipe heat insulation together and bind them with and vinyl tape so that there is no gap For left and left rear piping wrap the area which accommodates the rear p...

Страница 9: ...not be changed if invalid numbers or setting values are selected Refer to the installation manual enclosed with the remote control unit when the wired remote control unit option is used Entering the Function Setting Mode While pressing the POWERFUL button and SET TEMP simultaneously press the RESET button to enter the function setting mode STEP 1 Selecting the Remote Controller Signal Code Use the...

Страница 10: ...ate by the control unit or external input device Indoor room temperature sensor switching function Only for Wired remote controller The following settings are needed when using the Wired remote controller temperature sensor Ƈ Factory setting Setting Description Function Number Setting Value Ƈ No 42 00 Yes 01 If setting value is 00 Room temperature is controlled by the indoor unit temperature senso...

Страница 11: ... terminal L error Ɣ 6 Ɣ 10 Display PCB microcomputers communication error Ɣ 7 Ɣ 1 Discharge temp sensor error Ɣ 7 Ɣ 2 Compressor temp sensor error Ɣ 7 Ɣ 3 Outdoor unit Heat Ex liquid temp sensor error Ɣ 7 Ɣ 4 Outdoor temp sensor error Ɣ 7 Ɣ 5 Suction Gas temp sensor error Ɣ 7 Ɣ 6 2 way valve temp sensor error 3 way valve temp sensor error Ɣ 7 Ɣ 7 Heat sink temp sensor error Ɣ 8 Ɣ 2 Sub cool Heat E...

Страница 12: ... 7 9 3 Rimozione del pannello frontale 1 Rimuovere la griglia di aspirazione consultare le istruzioni per la rimozione della griglia di aspirazione 2 Rimuovere la copertura del cavo 3 Rimuovere le 3 viti ...

Страница 13: ... INSTALLATION Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN Solo para personal autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir INSTALLATION...

Страница 14: ...the composition of the gas and liquid phases And always charge from the liquid phase where refrigerant composition is stable 2 2 Special tools for R410A Tool name Contents of change Gauge manifold Pressure is high and cannot be measured with a conven tional R22 gauge To prevent erroneous mixing of other refrigerants the diameter of each port has been changed It is recommended the gauge with seals ...

Страница 15: ...ight of the outdoor units and install positively so that the units will not topple or fall CAUTION Do not install where there is the danger of combustible gas leakage Do not install near heat sources In places where the outdoor temperature drops to 0 ÛC or lower the drain water may freeze and may stop up the drain or cause other outdoor unit trouble Therefore take measures so that the drain water ...

Страница 16: ... Bend the pipe with a radius of curvature of 70mm or over 3 If the copper pipe is bend the pipe or pulled to often it will become stiff Do not bend the pipes more than three times at one place Tighten with two wrenches Torque wrench Wrench xed Flare nut Indoor unit pipe Connection pipe To prevent gas leakage coat the Àare surface with refrigerator oil Table 1 Flare nut size and tightening torque F...

Страница 17: ... TIMER indicator lamp of the indoor unit will simultaneously Àash slowly OUTDOOR UNIT 1 Is there any abnormal noise and vibration during operation 2 Will noise wind or drain water from the unit disturb the neighbors 3 Is there any gas leakage 6 PUMP DOWN 6 1 Pump down PUMP DOWN OPERATION FORCED COOLING OPERATION To avoid discharging refrigerant into the atmosphere at the time of relocation or disp...

Отзывы: