Temperature Setback Timer
• The temperature setback timer only changes the set temperature for 7 days, it cannot be used
to start or stop air conditioner operation.
• The temperature setback timer can be set to operate up to two times per day but only one
temperature setting can be used.
• During COOLING/DRY mode, the air conditioner will operate at a minimum of 64°F (18°C)
even if the SET BACK temperature is set to 63°F (17°C) or lower.
Case of Temperature Setback Timer on the Cooling operation. (Setting temperature :72°F
[22°C], SET BACK temperature :78°F [26°C])
SET BACK setting
Operation
temperature
Operation
temperature
*1
ON
OFF
OFF
ON
*1: During the SET BACK function,
the setting temperature is changed.
Chenge the setting temperature:
72°F (22°C) 75°F (24°C)
72°F (22°C)
78°F (26°C)
75°F (24°C)
72°F (22°C)
78°F (26°C)