![Fujitsu AOUH09LPAS1 Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/fujitsu/aouh09lpas1/aouh09lpas1_service-manual_2344153103.webp)
Model: AOUH12LPAS1
Fan speed is defined by outdoor temperature and rotation number of compressor.
•
Outside air temperature zone selection
Outside air
temperature rises
Z zone
Y zone
F zone
G zone
Outside air
temperature drops
H zone
53.6°F
(
12
°C)
35.6°F
(
2
°C)
50.0
°F
(
10
°C)
32.0
°F
(
0
°C)
17.6°F
(
-8
°C)
14.0°F
(
-10
°C)
69.8°F
(
21
°C)
66.2
°F
(
19
°C)
Unit: rpm
Fan step
Cooling
Heating
Dry
Cooling or dry at low outdoor temp.
Y zone
Y zone
Z zone
F zone
G zone
H zone
S-HIGH2
—
1,070
—
—
—
—
—
S-HIGH1
990
1,070
—
—
—
—
—
HIGH
990
1,070
—
—
—
—
—
10
—
1,070
—
—
—
—
—
9
990
1,070
990
350
260
200
170
8
850
1,070
850
350
260
200
170
7
820
850
820
350
260
200
170
6
820
820
820
250
200
170
170
5
820
700
820
220
200
170
170
4
740
610
740
220
200
170
170
3
660
510
660
220
200
170
170
2
610
510
610
220
200
170
170
1
600
510
600
220
200
170
170
NOTE:
After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor rotation number.
Fan speed after defrost control: 1,070 rpm
3-2. Outdoor fan control
- (04-15) -
3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Содержание AOUH09LPAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2022 10 18 SR_CH01_AS050EF_02 ...
Страница 14: ...2 2 Outdoor unit 01 8 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Страница 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 15 SR_CH02_AS050EF_02 ...
Страница 39: ...3 TROUBLESHOOTING 2021 07 XX SR_CH03_AS050EF_01 ...
Страница 41: ...5 2 Outdoor unit 03 43 CONTENTS continued ...
Страница 42: ......
Страница 87: ...4 CONTROL AND FUNCTIONS 2021 07 XX SR_CH04_AS050EF_01 ...
Страница 123: ...5 FILED WORKING 2021 06 28 SR_CH05_AS050EF_03 ...