EXTERNAL INPUT & OUTPUT
11.
Connector
INPUT
OUTPUT
REMARKS
CN303
Control input
-
See external input/
output settings for
details.
CN304
-
Operation status
output
EXTERNAL INPUT
11-1.
CONTROL INPUT (Operation/Stop)
The air conditioner can be remotely operated by means of the following on-site work.
Operation is started at the following contents by adding the contact input of a commercial ON/OFF switch to a
connector on the external control PC board and turning it ON.
Initial starting after power turned on
Starting other than at the left
Operation mode
Auto changeover
Mode at previous operation
Set temperature
24°C
Temperature at previous operation
Air flow mode
AUTO
Mode at previous operation
Up-down air direction (swing)
Standard air direction (swing OFF)
Air direction at previous operation
Left-right air direction (swing)
Standard air direction (swing OFF)
Air direction at previous operation
Circuit diagram example
Signal
Field supply
Indoor
control PC board
Communication kit
Optional parts
Connector
1
3
*10 m
Connected unit
Ex.) Switch
Operation
Stop
ON
OFF
Input signal
Indoor unit
Parts (Optional)
Parts name
Model name
External connect kit
UTY-XWZX
Communication box kit
UTY-XCBXE
* For operating the EXTERNAL INPUT function, the Compact wall mounted type requires the communication kit
(UTY-XCBXE) in addition to the wire (UTY-XWZX).
Wire (External input) : UTY-XWZX
Содержание AO*09LECN
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS A09LEC AS A12LEC DTR_AS047E_01 2010 10 05 ...
Страница 18: ... 01 15 WALL MOUNTED TYPE AS A09 12LE WALL MOUNTED TYPE AS A09 12LE SOUND LEVEL CHECK POINT 8 2 ...
Страница 27: ...2 OUTDOOR UNIT SINGLE TYPE AO R09LECN AO R12LECN DTR_AO069E_01 2010 10 05 ...
Страница 32: ... 02 04 OUTDOOR UNIT AO R09 12LE OUTDOOR UNIT AO R09 12LE WIRING DIAGRAMS 4 MODEL AO R09LE AO R12LE ...
Страница 38: ... 02 10 OUTDOOR UNIT AO R09 12LE OUTDOOR UNIT AO R09 12LE SOUND LEVEL CHECK POINT 8 2 ...