WIRING DIAGRAMS

4. 

MODEL

 

  : AO

R09LE, AO

R12LE

Содержание AO*09LECN

Страница 1: ...AIR CONDITIONER Wall Mounted type INDOOR OUTDOOR AS A09LEC AS A12LEC AO R09LECN AO R12LECN DESIGN TECHNICAL MANUAL ...

Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS A09LEC AS A12LEC DTR_AS047E_01 2010 10 05 ...

Страница 3: ...NG CAPACITY 01 10 6 2 HEATING CAPACITY 01 11 7 FAN PERFORMANCE AND CAPACITY 01 12 7 1 AIR VELOCITY DISTRIBUTION 01 12 7 2 AIR FLOW 01 13 8 OPERATION NOISE 01 14 8 1 NOISE LEVEL CURVE 01 14 8 2 SOUND LEVEL CHECK POINT 01 15 9 ELECTRIC CHARACTERISTICS 01 16 10 SAFETY DEVICES 01 17 11 1 EXTERNAL INPUT 01 18 11 2 EXTERNAL OUTPUT 01 19 12 FUNCTION SETTING 01 20 12 1 INDOOR UNIT Setting by remote contro...

Страница 4: ...perated under extreme low outdoor temperature 25 C without trouble New model Freezing prevention of bace Structural improvements Expansion of mechanical space Improvement of cold proof specifications of parts Powerful Heating at low outdoor temperature Keeping the high heating capacity at low outdoor temperature 3 5 45 up 3 5 3 2 2 2 2 6 3 3 17 up 4 1 3 5 2 9 4 1 3 0 17 up 2 9 Heating capacity kW O...

Страница 5: ...e the front panel is easy to remove maintenance is also easy Inner drying operation This model is equipped with an inner drying function After the power is turned off the dry starts inside the air conditioner This prevents the growth of mold and bacteria inside the air conditioner Corresponds to maximum 20m long piping b DC compressor c a b a a c When operation starts the machine operates at high ...

Страница 6: ...L MOUNTED TYPE AS A09 12LE WALL MOUNTED TYPE AS A09 12LE Air conditioner filter features Apple catechin Filter Long life Ion Deodorization Filter Ion Deodorization Filter Apple catechin Filter Dirty Air Clean Air ...

Страница 7: ...n automatically corrects the temperature thermostat setting according to the timer setting to prevent excessive cooling and heating while sleeping 60min 1 C 2 C Timer setting Set temp 1 C 30min 60min 90min 2 C 3 C 4 C Set temp Timer setting Cooling operation dry operation When the sleep timer is set the set temperature automatically rises 1 C every hour The set temperature can rise up to a maximum...

Страница 8: ... used when installing the air conditioner and should not be used under normal conditions as it will cause the indoor unit s thermostat function to operate incorrectly If this button is pressed during normal operation the indoor unit will switch to test operation mode and the Indoor Unit s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously To stop the test operation...

Страница 9: ...5 1 60 0 25 1 99 Current Cooling Rated A 3 2 4 3 Max 6 0 6 5 Heating Rated 3 7 4 6 Max 9 5 9 0 EER Cooling kW kW 3 97 3 80 COP Heating 4 27 4 12 SENSIBLE CAPACITY Cooling kW 1 60 2 20 POWER FACTOR Cooling 87 91 Heating 89 92 Moisture removal l h pints h 1 3 2 7 1 8 3 8 Fan Airflow rate Cooling High m3 h 735 Med 595 Low 425 Quiet 285 Heating High 735 Med 595 Low 425 Quiet 285 Type Q ty Cross flow fan...

Страница 10: ... 01 07 WALL MOUNTED TYPE AS A09 12LE WALL MOUNTED TYPE AS A09 12LE DIMENSIONS 4 MODEL AS A09LE AS A12LE Unit mm ...

Страница 11: ...08 WALL MOUNTED TYPE AS A09 12LE WALL MOUNTED TYPE AS A09 12LE INSTALLATION PLACE Unit mm Outline of indoor unit 52 or more 70 or more 48 or more 100 or more 45 or more 63 or more 1800 or more 1500 or more ...

Страница 12: ... 01 09 WALL MOUNTED TYPE AS A09 12LE WALL MOUNTED TYPE AS A09 12LE WIRING DIAGRAMS 5 MODEL AS A09LE AS A12LE TO OUTDOOR UNIT ...

Страница 13: ...0 1 84 1 26 0 67 2 05 1 27 0 68 2 12 1 38 0 69 2 26 1 38 0 69 2 33 1 49 0 70 2 47 1 49 0 70 2 61 1 58 0 71 43 1 72 1 18 0 68 1 92 1 19 0 69 1 99 1 29 0 69 2 12 1 29 0 70 2 18 1 40 0 70 2 31 1 39 0 71 2 44 1 48 0 72 AFR 12 5 Indoor temperature CDB 18 21 23 25 27 29 32 CWB 12 15 16 18 19 21 23 Outdoor temperature CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 10 2 92 2 02 ...

Страница 14: ... 4 64 1 70 4 53 1 73 4 42 1 77 4 31 1 80 4 20 1 84 7 6 5 04 1 70 4 92 1 73 4 80 1 77 4 68 1 80 4 56 1 84 10 8 5 38 1 70 5 25 1 73 5 12 1 77 4 99 1 80 4 87 1 84 15 10 5 69 1 70 5 55 1 73 5 42 1 77 5 28 1 80 5 15 1 84 AFR 12 5 Indoor temperature CDB 16 18 20 22 24 Outdoor temperature CDB CWB TC PI TC PI TC PI TC PI TC PI 25 26 3 07 1 09 3 00 1 12 2 92 1 14 2 85 1 16 2 78 1 18 20 21 3 35 1 28 3 27 1 ...

Страница 15: ... 0 5 2 1 0 1 2 Unit m s m m TOP VIEW Vertical flap Up Horizontal flap Center 0 1 2 3 4 5 6 7 8 0 5 0 5 1 0 1 0 2 0 2 0 3 2 1 0 1 2 3 Unit m s m TOP VIEW Vertical flap Up Horizontal flap Right Left m 0 1 2 3 4 5 6 7 8 2 0 1 0 0 5 3 2 1 0 Unit m s m SIDE VIEW Vertical flap Up Horizontal flap Center m 0 1 2 3 4 5 6 7 8 2 0 1 0 0 5 3 2 1 0 Unit m s m SIDE VIEW Vertical flap Down Horizontal flap Center m 0 1 2...

Страница 16: ...r of rotations r p m Air flow HIGH 1440 735 m h 204 l s 432 CFM MED 1200 595 m h 165 l s 350 CFM LOW 920 425 m h 118 l s 250 CFM QUIET 680 285 m h 79 l s 168 CFM Fan speed Number of rotations r p m Air flow HIGH 1440 735 m h 204 l s 432 CFM MED 1200 595 m h 165 l s 350 CFM LOW 980 465 m h 129 l s 274 CFM QUIET 700 295 m h 82 l s 174 CFM ...

Страница 17: ...frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 High Quiet NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octave band sound pressure level dB 0dB 0 0002μbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 MODEL AS A12LE COOLING High Qui...

Страница 18: ... 01 15 WALL MOUNTED TYPE AS A09 12LE WALL MOUNTED TYPE AS A09 12LE SOUND LEVEL CHECK POINT 8 2 ...

Страница 19: ... Model Name AS A09LE AS A12LE Power Supply Voltage V 230 Frequency Hz 50 Max Operating Current A 9 5 11 0 Wiring Spec Circuit breaker A 15 Connection Cable mm2 1 5 Limited wiring length m 20 Wiring Spec Selected Sample Selected based on Japan Electrotechnical Standard and Codes Committee E0005 ...

Страница 20: ...OUNTED TYPE AS A09 12LE SAFETY DEVICES 10 Protection form Model AS A09LE AS A12LE Circuit protection Current fuse PCB 3 15A 250V Terminal protection Current thermal fuse 3A 250V 102 C Fan motor protection Terminal protection program MAX 120 15 C ...

Страница 21: ...de Auto changeover Mode at previous operation Set temperature 24 C Temperature at previous operation Air flow mode AUTO Mode at previous operation Up down air direction swing Standard air direction swing OFF Air direction at previous operation Left right air direction swing Standard air direction swing OFF Air direction at previous operation Circuit diagram example Signal Field supply Indoor contro...

Страница 22: ... control PC board Communication kit Connected unit Ex Relay unit 1 2 Signal Relay power supply V Connector 10 m 24V DC ON OFF Operation Stop Indoor unit Output signal Parts Optional Parts name Model name External connect kit UTY XWZX Communication box kit UTY XCBXE For operating the EXTERNAL INPUT function the Compact wall mounted type requires the communication kit UTY XCBXE in addition to the wi...

Страница 23: ... conditioner signal code initially set to If the signal code does not need to be selected press the MODE button and proceed to STEP 2 Press the TIMER MODE button and check that the indoor unit can receive signals 2 at the displayed signal code Press the MODE button to accept the signal code and proceed to STEP 2 3 The air conditioner signal code is set to A prior to shipment The remote controller ...

Страница 24: ... temperature correction 1 3 Auto Restart 1 4 Indoor Room Temperature Sensor 1 5 Remote controller Signal Code 1 1 Setting the Cooler Room Temperature Correction Depending on the installed environment the room temperature sensor may require a correction The settings may be selected as shown in the table below Factory setting Setting Description Function Number Setting Value Standard 30 00 Lower con...

Страница 25: ...elect the signal code of the remote controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code Press the START STOP button until only the clock is displayed on the remote 1 controller display Press the MODE button for at least five seconds to display the current signal code 2 initially set to Press the SET TEMP 3 button to chang...

Страница 26: ...tracted from apples Ion deodorization filter UTR FA16 2 The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra fine particle ceramic Communication box kit UTY XCBXE Use to connect with optional devices and air conditioner PC board SU MO TU WE TH FR SA AM PM 3 6 9 12 15 18 21 Wired remote controller UTB UD Unit control is ...

Страница 27: ...2 OUTDOOR UNIT SINGLE TYPE AO R09LECN AO R12LECN DTR_AO069E_01 2010 10 05 ...

Страница 28: ...REFRIGERANT CIRCUIT 02 03 4 WIRING DIAGRAMS 02 04 5 CAPACITY COMPENSATION RATE FOR PIPE LENGTH AND HEIGHT DIFERENCE 02 05 6 ADDITIONAL CHARGE CALCULATION 02 07 7 AIR FLOW 02 08 8 OPERATION NOISE 02 09 8 1 NOISE LEVEL CURVE 02 09 8 2 SOUND LEVEL CHECK POINT 02 10 9 ELECTRIC CHARACTERISTICS 02 11 10 SAFETY DEVICES 02 12 ...

Страница 29: ... Heating 1 760 1 700 Type Q ty Propeller fan 1 Motor output W 50 Sound pressure level Cooling dB A 48 49 Heating 47 48 Heat exchanger type Dimensions H W D mm 508 896 22 504 896 18 2 Fin pitch 1 3 1 4 Rows x Stages 1 20 2 24 Pipe type Copper Fin type Aluminium Compressor Type Q ty Rotary 1 Motor output W 750 Refrigerant Type R410A Charge g 950 1 000 Refrigerant oil Type POE VG74 Enclosure Material...

Страница 30: ...r that is stated the condition will be the same as that are no obstacles 600 mm or more 100 mm or more 200 mm or more 100 mm or more 250 mm or more Service space DIMENSIONS 2 MODEL AO R09LE AO R12LE Unit mm Pitch of bolts for installation Drain port Ø20 353 320 45 4 540 125 395 20 790 540 20 68 290 ...

Страница 31: ... REFRIGERANT CIRCUIT 3 MODEL AO R09LE AO R12LE 2 Way valve Strainer Strainer 3 Way valve Muffler 4 Way valve Expansion valve Heat exchanger INDOOR Heat exchanger OUTDOOR Compressor Cooling Heating Refrigerant pipe diameter Liquid 1 4 6 35 mm Gas 3 8 9 52 mm ...

Страница 32: ... 02 04 OUTDOOR UNIT AO R09 12LE OUTDOOR UNIT AO R09 12LE WIRING DIAGRAMS 4 MODEL AO R09LE AO R12LE ...

Страница 33: ...0 990 0 969 10 1 002 0 990 0 969 7 5 1 001 1 002 0 990 0 969 5 1 000 1 001 1 002 0 990 0 969 0 1 000 1 001 1 002 0 990 0 969 2 Indoor unit is under than outdoor unit 5 0 995 0 996 0 997 0 985 0 964 7 5 0 994 0 995 0 983 0 962 10 0 992 0 980 0 960 15 0 970 0 950 COOLING Pipe length m 5 7 5 10 15 20 Height difference H m 1 Indoor unit is upper than outdoor unit 15 0 913 0 922 10 0 963 0 928 0 937 7 ...

Страница 34: ...7 5 1 010 1 002 0 952 0 932 5 1 000 1 010 1 002 0 952 0 932 0 1 000 1 010 1 002 0 952 0 932 2 Indoor unit is under than outdoor unit 5 0 995 1 005 0 997 0 947 0 927 7 5 1 002 0 994 0 945 0 925 10 0 992 0 942 0 923 15 0 933 0 913 COOLING Pipe length m 5 7 5 10 15 20 Height difference H m 1 Indoor unit is upper than outdoor unit 15 0 882 0 880 10 0 943 0 896 0 894 7 5 0 968 0 947 0 900 0 898 5 0 992...

Страница 35: ...ODEL AO R09LE REFRIGERANT CHARGE MODEL AO R12LE REFRIGERANT CHARGE Refrigerant type R410A Refrigerant amount g 950 Pipe length m 15 20 20g m Additional charge g 0 Charge less 100 Refrigerant type R410A Refrigerant amount g 1000 Pipe length m 15 20 20g m Additional charge g 0 Charge less 100 ...

Страница 36: ...TING MODEL AO R12LE COOLING HEATING Number of rotations r p m Air flow 850 2020 m3 h 561 l s 1189 CFM Number of rotations r p m Air flow 750 1760 m3 h 489 l s 1036 CFM Number of rotations r p m Air flow 850 1950 m3 h 542 l s 1148 CFM Number of rotations r p m Air flow 750 1700 m3 h 472 l s 1000 CFM ...

Страница 37: ... 0002μbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HEATING Octave band sound pressure level dB 0dB 0 0002μbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Octav...

Страница 38: ... 02 10 OUTDOOR UNIT AO R09 12LE OUTDOOR UNIT AO R09 12LE SOUND LEVEL CHECK POINT 8 2 ...

Страница 39: ...IT AO R09 12LE ELECTRIC CHARACTERISTICS 9 Model Name AO R09LE AO R12LE Power Supply Voltage V 230 Frequency Hz 50 Starting Current A 3 2 4 0 Wiring Spec Selected Sample Selected based on Japan Electrotechnical Standard and Codes Committee E0005 ...

Страница 40: ...R THE TERMINAL 20A 250V Current fuse MAIN PRINTED CIRCUIT BOARD 3 15A 250V Fan motor protection Thermal protection program OFF 100 15 10 C ON 95 15 10 C Compressor protection Thermal protection program DISCHARGE TEMP OFF 110 C ON After 7 minutes Heater protection Current fuse 5A 250V 2pcs Thermal protection switch HEATER TEMP OFF 55 3 3 C ON 45 4 4 C ...