SAFETY DEVICES
10.
Protection form
Model
AO
R09LE
AO
R12LE
Circuit protection
Current fuse (NEAR THE TERMINAL)
20A 250V
Current fuse
(MAIN PRINTED CIRCUIT BOARD)
3.15A 250V
Fan motor protection
Thermal protection program
OFF:100
+15
-10
°C
ON:95
+15
-10
°C
Compressor protection
Thermal protection program
(DISCHARGE TEMP.)
OFF:110°C
ON: After 7 minutes
Heater protection
Current fuse
5A 250V (2pcs)
Thermal protection switch
(HEATER TEMP.)
OFF:55
+3
-3
°C
ON:45
+4
-4
°C