FUNCTION SETTING
12.
INDOOR UNIT (Setting by remote controller)
12-1.
This procedure changes to the function settings used to control the indoor unit according to the
•
installation conditions. Incor settings can cause the indoor unit malfunction.
After the power is turned on, perform the “FUNCTION SETTING” according to the installation
•
conditions using the remote controller.
The settings may be selected between the following two: Function Number or Setting Value.
•
Settings will not be changed if invalid numbers or setting values are selected.
•
FUNCTION SETTING METHOD (for Wireless remote controller)
Entering the Function Setting Mode
While pressing the FAN button and SET TEMP. (
•
) simultaneously, press the RESET button to enter the function
setting mode.
STEP 1
Setting the Remote controller Signal Code
Use the following steps to select the signal code of the remote controller. (Note
that the air conditioner cannot receive a signal code if the air conditioner has not
been set for the signal code.) The signal codes that are set through this process are
applicable only to the signals in the FUNCTION SETTING. For details on how to set
the signal codes through the normal process, refer to SELECTING THE REMOTE
CONTROLLER SIGNAL CODE.
Press the SET TEMP. (
1.
) ( ) button to change the signal code between →
→ → Match the code on the display to the air conditioner signal code. (initially
set to )
(If the signal code does not need to be selected, press the MODE button and
proceed to STEP 2.)
Press the TIMER MODE button and check that the indoor unit can receive signals
2.
at the displayed signal code.
Press the MODE button to accept the signal code, and proceed to STEP 2.
3.
The air conditioner signal code is set to A prior to shipment.
The remote controller resets to signal code A when the batteries in the remote controller are replaced. If you use a
signal code other than signal code A, reset the signal code after replacing the batteries.
If you do not know the air conditioner signal code setting, try each of the signal codes ( → → → ) until you
find the code which operates the air conditioner.
STEP 2
Selecting the Function Number and Setting Value
Press the SET TEMP. (
1.
) ( ) buttons to select the function
number.
(Press the MODE button to switch between the left and right
digits.)
Press the FAN button to proceed to setting the value.
2.
Press the FAN button again to return to the function number
selection.)
Press the SET TEMP. (
3.
) ( ) buttons to select the setting
value.
(Press the MODE button to switch between the left and right
digits.)
Press the TIMER MODE button, and START/STOP button,
4.
in the order listed to confirm the settings.
Press the RESET button to cancel the function setting
5.
mode.
After completing the FUNCTION SETTING, be sure to turn
6.
off the power and turn it on again.
Function number
Setting value
CAUTION
After turning off the power, wait 10 seconds or more before turning on it again.
The FUNCTION SETTING doesn’t become effective if it doesn’t do so.
Содержание AO*09LECN
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS A09LEC AS A12LEC DTR_AS047E_01 2010 10 05 ...
Страница 18: ... 01 15 WALL MOUNTED TYPE AS A09 12LE WALL MOUNTED TYPE AS A09 12LE SOUND LEVEL CHECK POINT 8 2 ...
Страница 27: ...2 OUTDOOR UNIT SINGLE TYPE AO R09LECN AO R12LECN DTR_AO069E_01 2010 10 05 ...
Страница 32: ... 02 04 OUTDOOR UNIT AO R09 12LE OUTDOOR UNIT AO R09 12LE WIRING DIAGRAMS 4 MODEL AO R09LE AO R12LE ...
Страница 38: ... 02 10 OUTDOOR UNIT AO R09 12LE OUTDOOR UNIT AO R09 12LE SOUND LEVEL CHECK POINT 8 2 ...