CONTENTS OF FUNCTION SETTING
Follow the instructions in the Local Setup Procedure, which is supplied with the remote control, in
•
accordance with the installed condition.
After the power is turned on, perform the Function Setting on the remote control.
The settings may be selected between the following two: Function Number or Setting Value.
•
Settings will not be changed if invalid numbers or setting values are selected.
•
Wall
Mounted
1-1
Cooler room temperature correction
●
1-2
Heater room temperature correction
●
1-3
Auto Restart
●
1-4
Indoor Room Temperature Sensor
●
1-5
Remote controller Signal Code
●
1-1. Setting the Cooler Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be selected as shown in the table below.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Standard
30
00
Lower control
01
1-2. Setting the Heater Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be changed as shown in the table below.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Standard
31
00
Lower control
01
Slightly warmer control
02
Warmer control
03
Содержание AO*09LECN
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS A09LEC AS A12LEC DTR_AS047E_01 2010 10 05 ...
Страница 18: ... 01 15 WALL MOUNTED TYPE AS A09 12LE WALL MOUNTED TYPE AS A09 12LE SOUND LEVEL CHECK POINT 8 2 ...
Страница 27: ...2 OUTDOOR UNIT SINGLE TYPE AO R09LECN AO R12LECN DTR_AO069E_01 2010 10 05 ...
Страница 32: ... 02 04 OUTDOOR UNIT AO R09 12LE OUTDOOR UNIT AO R09 12LE WIRING DIAGRAMS 4 MODEL AO R09LE AO R12LE ...
Страница 38: ... 02 10 OUTDOOR UNIT AO R09 12LE OUTDOOR UNIT AO R09 12LE SOUND LEVEL CHECK POINT 8 2 ...