En-43
Error display mode
10. 2.
Mode
Code
Description
Mode
Code
Description
Communication
error
E 1 3. 1 Communication error between Outdoor unit
Outdoor unit actua-
tor error
E 9 2. 1 Compressor 2 error
E 1 4. 1 Outdoor unit network communication 1 error
E 9 2. 2 Compressor 2 overcurrent error
E 1 4. 2 Outdoor unit network communication 2 error
E 9 3. 1 Inverter compressor start up error
E 1 4. 5 The number of indoor unit shortage
E 9 4. 1 Trip detection
Function setting
error
E 2 8. 1 Auto address setting error
E 9 5. 5 Compressor motor loss of synchronization
E 2 8. 4 Signal ampli
fi
er auto address error
E 9 7. 1 Outdoor unit fan motor lock error
Indoor unit actuator
error
E 5 U. 1 Indoor unit error
E 9 7. 4 Outdoor unit fan motor undervoltage
Outdoor unit PCB/
Electrical compo-
nent/ Switch error
E 6 1. 5 Outdoor unit reverse phase wire error
E 9 7. 5 Outdoor unit fan motor
E 6 2. 3 Outdoor unit EEPROM access error
E 9 U. 2 Slave unit error
E 6 2. 6 Inverter communication error
Refrigerant system
abnormal
E A 1. 1 Discharge temperature 1 abnormal
E 6 2. 8 EEPROM data corrupted error
E A 2. 1 Discharge temperature 2 abnormal
E 6 3. 1 Inverter error
E A 3. 1 Compressor1 temperature abnormal
E 6 7. 2 Inverter PCB short interruptions detection
E A 3. 2 Compressor2 temperature abnormal
E 6 8. 1 Magnetic relay error
E A 4. 1 High pressure abnormal
E 6 8. 2 Rush current limiting resistor temp rise protection
E A 4. 2 High pressure protection1
E 6 9. 1
Outdoor unit transmission PCB Parallel
communication error
E A 4. 3 High pressure protection2
Outdoor unit sensor
error
E 7 1. 1 Discharge Temp Sensor1 Error
E A 5. 1 Low pressure abnormal
E 7 1. 2 Discharge Temp Sensor2 Error
E A C. 4 Heat sink temperature abnormal
E 7 2. 1 Compressor Temp Sensor1 Error
E 7 2. 2 Compressor Temp Sensor2 Error
E 7 3. 3 Outdoor unit Heat Ex. liquid temp. sensor error
E 7 4. 1 Outdoor Temp Sensor Error
E 7 5. 1 Suction Gas Temp Sensor Error
E 7 7. 1 Heat sink temp. sensor error
E 8 2. 1 Sub-cool Heat Ex. gas inlet temp. sensor error
E 8 2. 2 Sub-cool Heat Ex. gas outlet temp. sensor error
E 8 3. 1 Liquid pipe temp. sensor1 error
E 8 3. 2 Liquid pipe temp. sensor2 error
E 8 4. 1 Current sensor error
E 8 6. 1 Discharge pressure sensor error
E 8 6. 3 Suction pressure sensor error
E 8 6. 4 High pressure switch 1 error
E 8 6. 5 High pressure switch 2 error
㪃㪃
㪃
㪃
㪃
㪃
㪃
㪃
㪃
㪃
㪃
㫋㪑
㪣㪑
㪎㪑
㪟㪑
㪡㪑
㪍㪑
㪘㪑
㪚㪑
㪜㪑
㪝㪑
㪃
㪃
㪃
㪻㪑
㫅㪑
㫆㪑
㫉㪑
㪃
㪃
㪃
㪃
㪃
㪐㪑
㪧㪑
㪬㪑
㪪㪑
㪏㪑
㪃
㪃
㪃
㪃
㪌㪑
㪊㪑
㪋㪑
㪈㪑
㪉㪑
7 segment LED display:
9378945029-03_IM_EN.indb 43
9378945029-03_IM_EN.indb 43
2011-9-20 16:26:05
2011-9-20 16:26:05