176
Chapter 7 Configuring Hardware and Utilities
7.2.17 Console Redirection Submenu
This submenu is for console redirection settings.
table: Console Redirection submenu
Item
Setting
Description
Port
• Disabled (Initial value)
• Serial 1
Sets whether to enable the console redirection.
When "Serial 1" is set, set the following items.
Baud Rate
• 1200
• 2400
• 4800
• 9600 (Initial value)
• 19.2K
• 38.4K
• 57.6K
• 115.2K
Sets the baud rate used in the console redirection.
Protocol
• PC-ANSI
• VT100+ (Initial value)
• ASCII
• VT100
• VT100,8bit
• PC-ANSI,7bit
Sets the console type for the console redirection.
Flow Control
• CTS/RTS (Initial value)
• None
• XON/XOFF
Sets flow control for the console redirection.
Console connection
• Direct (Initial value)
• Via modem
Sets the console redirection connection.
Mode
• Standard (Initial value)
• Enhanced
Sets the range of use for console redirection.
# of video pages to
support
• 1 (Initial value)
• 1 to 8
Sets video pages of the console redirection.
Item Specific Help
Change Values
Enter
F9
Select Item
Select Menu
Select Sub-Menu
-/+
F1
Esc
Info
Exit
F10
Setup Defaults
Save and Exit
Console Redirection
[Disabled]
[9600]
[VT100+]
[CTS/RTS]
[Direct]
[Standard]
[ 1 ]
Port :
Baud Rate :
Protocol :
Flow Control :
Console connection :
Mode :
# of video pages to support :
Power
Server
Boot
Phoenix TrustedCore(tm) Setup Utility
Содержание 1PRIMERGY RX600 S4
Страница 12: ...12 ...
Страница 42: ...42 Chapter 1 Overview ...
Страница 114: ...114 Chapter 5 High Reliability Tools ...
Страница 180: ...180 Chapter 7 Configuring Hardware and Utilities ...
Страница 218: ...218 Chapter 8 Operation and Maintenance ...