Replacing a failed internal hard disk unit
When a hard disk is failed, it can be replaced and repaired without turning off the server and peripheral
devices (hot-swappable/hot-pluggable). For details about the array system and replacing the failed hard
disk unit, refer to the manual in Array Controller Document & Tool CD.
6.6.3 How to Install Internal Hard Disk Units
1
Turn off the server and connected devices, and unplug all power cables from
the outlet.
2
Touch a metal part of the server to discharge static electricity.
3
Remove a dummy unit from the bay in which you want to install an internal hard
disk unit.
Pull the dummy unit out towards you with its tabs being pressed inward.
Be sure to keep the removed dummy unit for later use.
4
Install an internal hard disk unit into the server.
1. Insert a hard disk unit into the 2.5-inch storage bay with the cover of the internal
hard disk unit open.
Press both