Chapter 7 Configuring Hardware and Utilities
7.1 Jumper Settings
This section explains jumper settings.
7.1.1 Jumper Location and Settings
Jumper location
The jumper of the server is located on the baseboard as shown below.
Jumper settings
Each jumper's meaning and setting are as follows.
table: Jumper settings
Jumper number
Meaning
Setting value
Description
J3C2
BIOS password
1-2 (Initial value)
2-3
To disable or delete the password, set "2-3".
J3C3
CMOS
1-2 (Initial value)
2-3
To clear CMOS, set "2-3".
3
2
1
J3C2
3
2
1
J3C3