U41117-J-Z125-7-76
379
XTCC
ESCON/FICON host adapter
8.8 ESCON/FICON host adapter
8.8.1
Object information for the ESCON/FICON host adapter
Each host adapter is represented by a block at the top of the ICP. Within the block, the host
adapter number (HA #0, HA #1, etc.) and type (ESCON, FICON, FC) are displayed. The
status of the host adapter is indicated by the colors pink (not active), green (active) and
yellow (unknown).
●
Example for an ESCON host adapter
In the host adapter symbol, the serial number of the host adapter in the ICP appears in
the top line (here: HA #0) and the interface type appears in the second line (here:
ESCON).
The following information is also displayed in the information box:
Adapter Status
Active or stopped.
Firmware Level
Firmware version.
Hardware Level
Hardware version.
Cluster Number
Always 0 in CentricStor.
Board Number
Number of the adapter board.
Board Type
Board type.
Bus Type
Bus type.
Bus Number
Bus number.
Device Number
Position of the ESCON host adapter in the ICP bus system.
Port Number
Port number.
Node ID
Node ID of the ESCON host adapter.
Partner Node ID
Node ID at the other end of the ESCON connection (usually the
ESCON Director).
Содержание CentricStor V3.1D
Страница 1: ...Edition July 2007 CentricStor V3 1D User Guide...
Страница 22: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 60: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 236: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 311: ...U41117 J Z125 7 76 311 Global Status History diagrams Example for V3 1D...
Страница 321: ...U41117 J Z125 7 76 321 Global Status History diagrams 4 Open history file...
Страница 322: ...322 U41117 J Z125 7 76 History diagrams Global Status 5 Confirm you wish to open it...
Страница 324: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 544: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 546: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...