U41117-J-Z125-7-76
75
Selected system administrator activities
Reorganization
4.4.3
When is a reorganization performed?
Depending on the type of event or status which triggers reorganization, the PLM performs
reorganization either immediately after the event occurs or within a configurable time of day
interval.
The following three events cause reorganization to be triggered immediately regardless of
the time of day:
●
Explicitly by means of a user command
It is possible for the user to explicitly request the reorganization of a physical volume via
the GXCC user interface (see
section “Starting the reorganization of a physical volume”
on page 78
). This event has priority over all other reasons for reorganization which may
occur simultaneously. Any reorganization which may be running for the physical volume
group concerned is aborted.
●
Hard minimum event
This event has occurred whenever one of the following two conditions are fulfilled:
–
The number of scratch tapes falls below the hard minimum specified in the GXCC
menu “
Physical Volume Groups
” (see
page 187
).
–
There are read tapes present with any occupancy level.
If the number of scratch tapes falls below the hard minimum, the following system
message is issued (see
page 75
):
SXPL008 ... PLM(#8): WARNING: hard minimum of free PVs (<num>) of PV-
group <PVG> reached
Once the number of scratch tapes exceeds the hard limit again, the “all clear” is given
(see
page 75
):
SXPL009 ... PLM(#9): NOTICE: number of free PVs of PV-group <PVG> over
hard minimum (<num>) again
●
Absolute minimum event
If the number of scratch tapes falls below the absolute minimum, the PLM will reject all
normal “Save” requests and will only process those issued in the context of the reorga-
nization.
This is because the PLM itself requires a number of scratch tapes for reorganization
purposes. Without these, it could find itself in a dead-lock situation.
If the number of scratch tapes falls below the hard minimum, the following message will
be written to the file
klog.msg
(see
page 76
):
SXPL010 ... PLM(#10): WARNING: absolute minimum of free PVs (<num>) of
PV-group <PVG> reached
Содержание CentricStor V3.1D
Страница 1: ...Edition July 2007 CentricStor V3 1D User Guide...
Страница 22: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 60: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 236: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 311: ...U41117 J Z125 7 76 311 Global Status History diagrams Example for V3 1D...
Страница 321: ...U41117 J Z125 7 76 321 Global Status History diagrams 4 Open history file...
Страница 322: ...322 U41117 J Z125 7 76 History diagrams Global Status 5 Confirm you wish to open it...
Страница 324: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 544: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 546: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...