54
U41117-J-Z125-7-76
Optional system functions
CentricStor - Virtual Tape Library
3. After the defective processor has been repaired, it is integrated once again into the
overall system and takes over the role of the SVLP:
Figure 20: Activation of the defective processor for the SVLP
The status, i.e. AutoVLP failover active or inactive, is clearly visible on the GUI:
Figure 21: Display of the AutoVLP failover status on the GUI
The left-hand triangle is only displayed if an SVLP is configured.
If the left-hand triangle below the VLP is green, this means that AutoVLP failover is
activated. If it is red, AutoVLP failover is not activated. In addition, the text “AutoVLP-
Failover OFF” is displayed in red in the text window on the right.
CAUTION!
The function must have the same status on the VLP and SVLP: enabled or not
enabled (ON or OFF).
When the AutoVLP failover function is configured and activated, VLP monitoring on this ISP
is activated automatically with every reboot.
ISP
ISP
VLP
SVLP
Activation
FC fabric
i
!
Содержание CentricStor V3.1D
Страница 1: ...Edition July 2007 CentricStor V3 1D User Guide...
Страница 22: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 60: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 236: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 311: ...U41117 J Z125 7 76 311 Global Status History diagrams Example for V3 1D...
Страница 321: ...U41117 J Z125 7 76 321 Global Status History diagrams 4 Open history file...
Страница 322: ...322 U41117 J Z125 7 76 History diagrams Global Status 5 Confirm you wish to open it...
Страница 324: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 544: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...
Страница 546: ...Eine Dokuschablone von Frank Flachenecker by f f 1992...