![FujiFilm FRN001E1E-2U Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/fujifilm/frn001e1e-2u/frn001e1e-2u_brochure_2343269036.webp)
1/8
1/4
1/2
1
2
3
5
7.5
10
15
20
1/2
1
2
3
5
7.5
10
15
20
1/8
1/4
1/2
1
2
3
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
5.5
14.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
5.5
14.0
22.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
5.5
2.0
2.0
2.0
2.0
2.0
3.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
3.5
8.0
14.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
5.5
8.0
14.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
5.5
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
2.0
2.0
3.5
5.5
8.0
FRNF12E1
□
-2U
FRNF25E1
□
-2U
FRNF50E1
□
-2U
FRN001E1
□
-2U
FRN002E1
□
-2U
FRN003E1
□
-2U
FRN005E1
□
-2U
FRN007E1
□
-2U
FRN010E1
□
-2U
FRN015E1
□
-2U
FRN020E1
□
-2U
FRNF50E1
□
-4U
FRN001E1
□
-4U
FRN002E1
□
-4U
FRN003E1
□
-4U
FRN005E1
□
-4U
FRN007E1
□
-4U
FRN010E1
□
4U
FRN015E1
□
-4U
FRN020E1
□
-4U
FRNF12E1
□
-7U
FRNF25E1
□
-7U
FRNF50E1
□
-7U
FRN001E1
□
-7U
FRN002E1
□
-7U
FRN003E1
□
-7U
5
10
5
SC-05
SC-05
SC-05
SC-4-0
SC-5-1
SC-N1
SC-N2
SC-05
SC-05
SC-05
SC-5-1
SC-4-0
SC-5-1
SC-N1
SC-N2S
SC-N3
SC-05
SC-05
SC-05
SC-4-0
SC-5-1
SC-N1
SC-N2
SC-4-0
SC-5-1
SC-4-0
SC-N1
SC-4-0
SC-5-1
5
5
10
15
20
30
50
75
100
125
10
15
20
30
40
50
60
10
15
20
30
20
30
40
50
75
5
5
10
15
20
30
40
10
15
20
■
Devices requiring wiring
Power
supply
voltage
Applicable
motor rating
(HP)
Inverter type
With DCR Without DCR With DCR Without DCR
With DCR Without DCR
Output
circuit
MCCB, GFCI
rated current (A)
Magnetic contactor (MC)
Input circuit
Inverter
output
[U, V, W]
DC Reactor
[P1, P (+)]
DC Reactor
[P (+), DB
For
control
circuit
Three-
phase
230V
Three-
phase
460V
Single-
phase
230V
Main power input
(L1/R, L2/S, L3/T)
Recommended cable size (mm
2
)
*1
0.75
to
1.25
0.75
to
1.25
0.75
to
1.25
For connection
with Inverter
[ G]
Note1) An external power supply of 24V is needed to use a separately sold option card.
Note2) The inverter that can be used with the SY card includes special specifications. When ordering the SY card, please order together with the inverter in a set.
•
The frame and series of the MCCB and GFCI models vary according to the transformer capacity and so on of the equipment. Choose the optimum ones according to the catalog and technical data of the
circuit breaker and others.
•
Choose the optimum rated sensitive current of the ELCB according to technical data, too. The rated currents of the MCCB and GFCI specified in this table indicate those of SA
B/
and SA
R/
models.
•
Description in the above table may vary for different ambient temperatures, power supply voltages or other conditions.
*1: Use crimp terminals equipped with insulation sheath or those equipped with an insulation tube or the like.
The cable to be used is 600V-insulated cable with an allowable temperature of 75
˚
C(167
˚
F). The ambient temperature is assumed to be 50
˚
C(122
˚
F).
The code in
□
represents followings; S: standard model, E: EMC filter built-in type
Options
Содержание FRN001E1E-2U
Страница 1: ...MEH531 High Performance Compact Inverters...
Страница 38: ...MEMO...
Страница 39: ...MEMO...