![FujiFilm FRN001E1E-2U Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/fujifilm/frn001e1e-2u/frn001e1e-2u_brochure_2343269026.webp)
2 to 22
0.01 to 30.00 (where, P99 data is 0, 3, or 4.)
0.01 to 30.00 (where, P99 data is 1.)
0.00 to 100.0
0: Disable
1: Enable (Tune %R1 and %X while the motor is stopped.)
2: Enable (Tune %R1, %X and rated slip while the motor is stopped, and no-load current while running.)
0 : Disable
1 : Enable
0.00 to 50.00
0.00 to 50.00
0.00 to 50.00
0.0 to 200.0
0.00 to 10.00
0.0 to 200.0
0.00 to 15.00
0: Motor characteristics 0 (Fuji standard motors, 8-series)
1: Motor characteristics 1 (HP rating motors)
3: Motor characteristics 3 (Fuji standard motors, 6-series)
4: Other motors
2
0.01
0.01
0.01
-
-
0.01
0.01
0.01
0.01
0.01
0.01
0.01
-
Pole
kW
HP
A
-
-
A
%
%
%
s
%
Hz
-
Y1Y2
Y1Y2
Y1Y2
N
Y
Y1Y2
Y1Y2
Y1Y2
Y
Y1Y2
Y
Y1Y2
Y1Y2
(No. of poles)
(Rated capacity)
(Rated current)
(Auto-tuning)
(Online tuning)
(No-load current)
(%R1)
(%X)
(Slip compensation gain for driving)
(Slip compensation response time)
(Slip compensation gain for braking)
(Rated slip frequency)
4
Rated capacity
of motor
Rated value of Fuji standard motor
0
0
Rated value of Fuji standard motor
Rated value of Fuji standard motor
Rated value of Fuji standard motor
100.0
0.50
100.0
Rated value of Fuji standard motor
0
Data Initialization
Auto-reset
Cooling Fan ON/OFF Control
Acceleration/Deceleration Pattern
Limiting the direction of the motor rotation
Starting Mode
Deceleration Mode
Instantaneous Overcurrent Limiting
Restart Mode after Momentary Power Failure
Thermistor
Droop control
Communications Link Function
Capacitance of DC Link Bus Capacitor
Cumulative Run Time of Cooling Fan
Startup Times of Motor 1
Mock Alarm
Initial Capacitance of DC Link Bus Capacitor
Cumulative Run Time of Capacitors on Printed Circuit Boards
Starting Mode
Non-linear V/f Pattern,1
Non-linear V/f Pattern,2
ACC/DEC time
Deceleration Time for Forced Stop
(Times)
(Reset interval)
(Auto search)
(Mode selection)
(Restart time)
(Frequency fall rate)
(Allowable momentary power failure time)
(Mode selection)
(Level)
(Mode selection)
(Delay time)
(Frequency)
(Voltage)
(Frequency)
(Voltage)
(Jogging operation)
0: Disable initialization
1: Initialize all function code data to the factory defaults
2: Initialize motor 1 parameters
3: Initialize motor 2 parameters
0: Disable 1 to 10
0.5 to 20.0
0: Disable (Always in operation)
1: Enable (ON/OFF controllable)
0: Linear
1: S-curve (Weak)
2: S-curve (Strong)
3: Curvilinear
0: Disable
1: Enable (Reverse rotation inhibited)
2: Enable (Forward rotation inhibited)
0: Disable
1: Enable (At restart after momentary power failure)
2: Enable (At restart after momentary power failure and at normal start)
0: Normal deceleration
1: Coast-to-stop
0 : Disable
1 : Enable
0.1 to 10.0
0.00 : FSelected deceleration time 0.01 to 100.00
999: Follow the current limit command
0.0 to 30.0 999 : Automatically determined by inverter
0: Disable
1: Enable (With PTC, the inverter immediately trips with displayed.)0.00 to 5.00V
2: Enable (With PTC, the inverter issues output signal THM and continues to run.
0.00 to 5.00
-60.0 to 0.0
Frequency command
Run command
0: F01/C30
F02
1: RS-485
F02
2: F01/C30
RS-485
3: RS-485
RS-485
4: RS-485 (option)
F02
5: RS-485 (option)
RS-485
6: F01/C30
RS-485 (option)
7: RS-485
RS-485 (option)
8: RS-485 (option)
RS-485 (option)
Indication for replacing DC link bus capacitor (0000 to FFFF: Hexadecimal)
Indication of cumulative run time of cooling fan for replacement
Indication of cumulative startup times
0: Disable 1: Enable (Once a mock alarm occurs, the data automatically returns to 0.)
Indication for replacing DC link bus capacitor (0000 to FFFF: Hexadecimal)
Indication for replacing capacitors on printed circuit boards (0000 to FFFF: Hexadecimal). Resettable.
0.0 to 10.0
0.0 : Cancel 0.1 to 400.0
0 to 240 : Output an AVR-controlled voltage (for 230 V class series)
0 to 500 : Output an AVR-controlled voltage (for 460 V class series)
0.0 : Cancel 0.1 to 400.0
0 to 240: Output an AVR-controlled voltage (for 230 V class series)
0 to 500: Output an AVR-controlled voltage (for 460 V class series)
0.00 to 3600 *ACC time and DEC time are common.
0.00 to 3600
-
1
0.1
-
-
-
-
-
-
0.1
0.01
0.1
-
0.01
0.1
-
1
-
-
-
-
-
0.1
0.1
1
0.1
1
0.01
0.01
-
Times
s
-
-
-
-
-
-
s
Hz/s
s
-
V
Hz
-
-
-
-
-
-
-
s
Hz
V
Hz
V
s
s
N
Y
Y
Y
Y
Y
Y
Y
Y
Y1Y2
Y
Y
Y
Y
Y
Y
N
N
N
N
N
N
Y
Y
Y2
Y
Y2
Y
Y
0
0
5.0
0
0
0
0
0
1
Depending on the inverter capacity
999
999
0
1.60
0.0
0
-
-
-
0
Set at factory shipping
-
0.0
0.0
0
0.0
0
6.00
6.00
Motor 1
Motor 1 Selection
■
Functions Settings
●
H codes: High Performance Functions
●
P codes: Motor Parameters
Func.
Code
Data
copy
*2
Name
Data setting range
Default setting
Min.
Unit
Func.
Code
Data
copy
*2
Name
Data setting range
Default setting
Min.
Unit
Functions Settings