(Mode selection)
(Remote command SV)
P (Gain)
I (Integral time)
D (Differential time)
(Feedback filter)
(Anti reset windup)
(Select alarm output)
(Upper level alarm (AH))
(Lower level alarm (AL))
(Upper limit of PID process output)
(Lower limit of PID process output)
(Speed command filter)
(Dancer reference position)
(Detection width of Dancer position deviation )
P (gain) 2
I (Integration time) 2
D (Derivative time) 2
(Selection PID control block)
(PID control block Selection)
(Detection value)
(Detection level)
(Mode selection )
(Operation condition)
(Timer)
(Released current)
(Brake OFF frequency)
(Brake OFF timer)
(Brake ON frequency)
(Brake ON timer)
0 : Disable
1 : Enable (Process control, normal operation)
2 : Enable (Process control, inverse operation)
3 : Enable (Dancer control)
0 : UP/DOWN keys on keypad
1 : PID command 1
3 : Terminal command UP /DOWN control
4 : Command via communications link
0.000 to 30.000
*1
0.0 to 3600.0
*1
0.0 to 600.00
*1
0.0 to 900.0
0 to 200
0 : Absolute-value alarm
1 : Absolute-value alarm (with Hold)
2 : Absolute-value alarm (with Latch)
3 : Absolute-value alarm (with Hold and Latch)
4 : Deviation alarm
5 : Deviation alarm (with Hold)
6 : Deviation alarm (with Latch)
7 : Deviation alarm (with Hold and Latch)
-100 to 100
-100 to 100
-150 to 150 999 : F Disable
-150 to 150 999 : F Disable
0.00 to 5.00
-100 to 100
0 : Disable switching PID constant
1 to 100
0.000 to 30.00
*1
0.0 to 3600.0
*1
0.00 to 600.00
*1
Bit 0 : PID output pole 0 = addition, 1 = subtraction
Bit 1 : Select compensation of output ratio 0 = speed command, 1 = ratio
0 : Torque
1 : Current
20 to 200
0 : Disable
1 : Decelerate to stop
2 : Coast to a stop
3 : Hit mechanical stop
0 : Enable at constant speed and during deceleration
1 : Enable at constant speed
2 : Enable anytime
0.00 to 600.00
0 to 200
0.0 to 25.0
0.0 to 5.0
0.0 to 25.0
0.0 to 5.0
-
-
0.001
0.1
0.01
0.1
1
-
1
1
1
1
0.01
1
1
0.001
0.1
0.01
1
-
0.1
-
-
0.01
1
0.1
0.1
0.1
0.1
-
-
Times
s
s
s
%
-
%
%
%
%
s
%
%
times
s
s
-
-
%
-
-
s
%
Hz
s
Hz
s
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
0
0
0.100
0.0
0.00
0.5
200
0
100
0
999
999
0.10
0
0
0.100
0.0
0.00
0
0
100
0
0
0
100
1.0
1.0
1.0
1.0
Pole
kW
HP
A
-
-
A
%
%
%
s
%
Hz
-
-
-
-
-
2
0.01
0.01
0.01
-
-
0.01
0.01
0.01
0.01
0.01
0.01
0.01
-
-
0.01
-
-
Y1Y2
Y1Y2
Y1Y2
N
Y
Y1Y2
Y1Y2
Y1Y2
Y
Y1Y2
Y
Y1Y2
Y1Y2
Y
Y
N
N
4
4
Rated value of Fuji standard motor
0
0
Rated value of Fuji standard motor
Rated value of Fuji standard motor
Rated value of Fuji standard motor
100.0
0.50
100.0
Rated value of Fuji standard motor
0
0
0.20
-
-
Motor 2
Motor 2 Selection
Slip compensation 2
Output Current Fluctuation Damping Gain for Motor 2
Cumulative Motor Run Time 2
Startup Times of Motor 2
(No. of poles)
(Rated capacity)
(Rated current)
(Auto-tuning)
(ON-Line tuning)
(No-load current)
(%R1)
(%X)
(Slip compensation gain for driving)
(Slip compensation response time)
(Slip compensation gain for braking)
(Rated slip frequency)
(Operating conditions)
2 to 22
0.01 to 30.00 (where, P99 data is 0, 3, or 4.)
0.01 to 30.00 (where, P99 data is 1.)
0.00 to 100.0
0: Disable
1 : Enable (Tune %R1 and %X while the motor is stopped.)
2 : Enable (Tune %R1, %X and rated slip while the motor is stopped, and no-load current while running.)
0 : Disable
1 : Enable
0.00 to 50.00
0.00 to 50.00
0.00 to 50.00
0.0 to 200.0
0.00 to 10.00
0.0 to 10.00
0.00 to 15.00
0 : Motor characteristics 0 (Fuji standard motors, 8-series)
1 : Motor characteristics 1 (HP rating motors)
3 : Motor characteristics 3 (Fuji standard motors, 6-series)
4 : Other motors
0 : Enable during ACC/DEC and enable at base frequency or above
1 : Disable during ACC/DEC and enable at base frequency or above
2 : Enable during ACC/DEC and disable at base frequency or above
3 : Disable during ACC/DEC and disable at base frequency or above
0.00 to 0.40
Change or reset the cumulative data
Indication of cumulative startup times
PID Control
PID Control
Overload stop
Braking signal
■
Functions Settings
●
J codes: Application Functions
●
A codes: Motor 2 Parameters
Func.
Code
Data
copy
*2
Name
Data setting range
Default setting
Min.
Unit
Func.
Code
Data
copy
*2
Name
Data setting range
Default setting
Min.
Unit
Functions Settings
Содержание FRN001E1E-2U
Страница 1: ...MEH531 High Performance Compact Inverters...
Страница 38: ...MEMO...
Страница 39: ...MEMO...