MT6M16534
© Fuji Electric Co., Ltd. All rights reserved.
2-2
3.
Insert the removal part of the remover into the gap between the pin and the tube. (See Fig. 2-4)
2
Removing the product from the tube
• Since the elements installed in the Small IPM are extremely weak to electrostatic discharge,
appropriate ESD countermeasures are necessary in the assembly environment within the range
described in the specifications. In particular, when removing it out from the tube, it is most likely to
cause electrical damage to the product.
• When removing the product, do not strongly collide the products with each other or touch the
product terminals to the tube. A strong impact on the product may cause deforming or damage to
the product terminals.
4.
Hold the pin with your finger and remove the pin with the tube opening facing up.
(See Fig. 2-5, 2-6)
Fig. 2-5 How to hold the pin
Fig. 2-6 Tube opening orientation
Fig. 2-4 Insert remover
Insert the remover to reach to the
opposite side of the pin head