![Fuji Electric FSC-2 Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/fuji-electric/fsc-2/fsc-2_instruction-manual_2341885067.webp)
58
INF-TN2FSC-E
(5) Connect the signal cable and conversion cord
with BNC connector.
Water-proof grade of connector part is IP66
under the condition of interdigitation.
Please avoid using this in the water.
BNC connector
Conversion cord
Signal cable
8.7.2 How to mount large size sensor to pipe
(1) Height adjustment of guide plate
• Place the sensor on the pipe surface in parallel
with the pipe axis.
• Loosen the guide plate fixing screw and slide
the guide plate until its edge and transmitting
surface touch the surface of pipe.
• Then tighten the fixing screw.
Pipe
Guide plate
Fixing screw
Transmission
surface
Transmission
direction mark
(2) How to determine the length of wire rope
• Place the sensor on the marked lines and fit the
wire rope and fastening spring.
• Loosen the wire clip and pull the wire rope
until the overall length of fastening spring
approximates 180mm. Then tighten the wire
clip.
(The fastening spring has a free length of
110mm.)
• While fixing the wire rope, remove the sensor.
180
600
Sensor
Marked lines
Fastening
spring
Loosen this wire clip
and pull the wire rope.
Pipe