48
INF-TN2FSC-E
(7) If there is not much space to mount since pipe size is small and short length, one of guide rail
can be removed and use the rail as a half size as shown below.
However, it is available to use only if dimension of mounting pitch is 65mm or less.
Mounting
pitch
Rail end
Pipe
8.4.2 How to mount a detector (Z method)
(1) Confirm the mounting dimension in Item 7.1.
(2) Mark the mounting position on the pipe.
Please refer to Item 8.1 ~ 8.3 “How to determine the mounting position”.
(3) Preparation of the rail
• Set up the rail for Z method
1) Loosen the 4 screws which fix the extension rail (blue) and remove the guide rail.
2) Screw the each supplied rail end with 4 screws. (2pieces)
Rail end
Loosen the screw
(4) 8.4.1 Apply the acoustic coupler on the sensor unit as same as Item (4).