Fuji Electric FSC-2 Скачать руководство пользователя страница 1

Instruction Manual

PORTABLE TYPE 

ULTRASONIC FLOWMETER

TYPE:

 

FLOW TRANSMITTER  FSC-2

DETECTOR 

FSS-1, FSD-1

INZ-TN2FSCd-E

Содержание FSC-2

Страница 1: ...Instruction Manual PORTABLE TYPE ULTRASONIC FLOWMETER TYPE FLOW TRANSMITTER FSC 2 DETECTOR FSS 1 FSD 1 INZ TN2FSCd E...

Страница 2: ...2015 Rev 3rd edition Jan 2016 Rev 4th edition Jun 2016 This manual explains cautions in use wiring operation installation troubleshooting and maintenance and op tions of the portable type ultrasonic...

Страница 3: ...Turning on the power and language preference 18 5 3 Power OFF 19 6 WIRINg 20 6 1 Diagram 20 6 2 Connection of dedicated cables 20 6 3 Connection of analog input output cable 4 to 20 mA DC 21 6 4 Conn...

Страница 4: ...1 3 UNIT OF OUTPUT when changing unit of each output 73 10 1 4 OUTPUT CONTROL when controlling measured value output control function 75 10 1 5 TOTALIZER when performing the total process of measured...

Страница 5: ...rror 147 11 MAINTENANCE AND CHECKUP 150 12 ERROR AND REMEDY 153 12 1 Error in LCD Display 153 12 2 Error of key 153 12 3 Error in measured value 154 12 4 Error in analog output 157 13 EXTERNAL COMMUNI...

Страница 6: ...of this device is indicated by different symbols CAUTION Improper handling of this device may cause dangerous situations that result in personal injury or property damage The following symbols describ...

Страница 7: ...s such as paint thinner near the device Otherwise it may result in explosion or fire Pull out the plug immediately in case of an emergency In case of abnormal odor smoke or fire is perceived pull the...

Страница 8: ...Wipe the dust off the plug and insert it securely Otherwise it may result in electric shock or fire Match power capacity with the device ratings Fire hazard Be sure to connect the device to the power...

Страница 9: ...r etc which generate electromagnetic induction noise electrostatic noise etc Fire or damage may result Do not use in a place which is near cell phones wireless devices etc which may cause the machine...

Страница 10: ...talling a sensors on the outside of pipes A combination of the latest electronics and digital signal processing technologies enables the instrument to provide a compact and convenient solution to accu...

Страница 11: ...apter Power connector conversion cord Power cord Analog input output cord 1 5m USB cable 1m CD ROM Instruction manual INF TN2FSC E Loader Instruction manual INF TN5A1784 E Roll paper When 2 is selecte...

Страница 12: ...se Detector 4th digit of code symbol FSSC Rail 1 set Sensor unit 2 pieces Rail end as standard 2 pieces FSSD Flame 1 set Sensor unit 2 pieces FSSE Sensor unit 2 pieces FSSH Rail 1 piece Sensor unit 2...

Страница 13: ...are included 1 Main unit Small type Type FSDP2 Middle type Type FSDP1 Large type Type FSDP0 2 Accessories Fastening springs 2mm wire rope Plastic cloth belt Silicone grease Large type Small type Medi...

Страница 14: ...quired Power adapter AC power power cord 125V AC for Japanese and North American use AC power power cord 250V AC for European and Korean use AC power power cord 250V AC for Chinese use Modification No...

Страница 15: ...ilicone grease G40M Y A B C D Guide rail 5th digits Provided 1 Y A Water proof treatment 9th digit None Y Description Senser type 4th digits 50 to 400mm 40 to 200 C Mounting belt 6th digits None Stain...

Страница 16: ...iption S D 0 Y 1 1 2 3 4 5 6 7 8 Kind Small type 40 to 200mm Middle type 100 to 400mm Large type 200 to 1000mm Structure General use P P P 2 1 0 0 Y Application None 1 Modification No Small type Type...

Страница 17: ...ng all information of the ULTRASONIC FLOWMETER including print of display screen capture and printout of measured value ULTRASONIC FLOWMETER includes a logger function for storing measured values in m...

Страница 18: ...REAM upstream side DOWN STREAM downstream side Receptacles to connect detector cables Connect matching the upstream and downstream sides ANALOg IN OUT Connect analog input output signals 4 to 20mA DC...

Страница 19: ...the cursor downward decrements set value etc repeats if held down Moves the cursor leftward change scale etc repeats if held down Moves the cursor rightward change scale etc repeats if held down Turns...

Страница 20: ...memory card or SDHC memory card based on its standard 3 Firmly insert the SD memory card or SDHC memory card hereinafter the same in the appro priate direction and assure that it has been properly mo...

Страница 21: ...d with force in the state where the card is inserted as tilted the con nector in the main unit will be broken Be careful CAUTION 2 Removal Card push in system is adopted for card mounting Push the car...

Страница 22: ...of site name is created at the time of registration of a site name described in 10 1 1 SITE MEMORY The recorded data is stored in the folder of the site name selected by site selection described in 10...

Страница 23: ...Quick logger VEL Flow velocity distribution Vel_20060704_163100 csv Data Time Vel_20060705_163100 csv Date Time DISP Hard copy DISP_20060704_163100 bmp Date Time DISP_20060705_163100 bmp Date Time VAL...

Страница 24: ...minates with the following screen displayed Replace the SD memory card immediately if this screen is displayed Press the ESC key or remove the memory card the message will be cleared Note After reachi...

Страница 25: ...urned green indicates that external power dispatching CHARgE LED of the main unit is turned red indicates that it is on charging DC IN LED of the main unit is turned green indicates that external powe...

Страница 26: ...y prior to use Under fully charged condition the main unit can measure for about 12 hours Note Conditions Display backlight should be turned off do not use current output Ambient temperature is normal...

Страница 27: ...e Note2 To return to the Language Selection screen from the MEASUREMENT screen in display turn OFF the power once and then turn it ON again In the initial screen that is displayed press the ENT key EN...

Страница 28: ...cessing before turning OFF the power 3 Precautions for parameter setup change When parameter setup is changed parameters are stored in the internal non volatile memory at upon return to the measuremen...

Страница 29: ...or Power connector Conversion cord To connect PC PC Flow transmitter USB cable SD memory card for use AC adaptor Detector input the downstream side Detector input the upstream side 6 2 Connection of d...

Страница 30: ...ck AI ch2 AO AI ch1 1 Connect clips of the analog I O cable to the and sides of the receiving instruments respectively 2 Connect the analog I O cable to the AI AO connector at the side panel of the ma...

Страница 31: ...aution Measurements cannot be accomplished without these settings 7 1 Display of pipe setup screen 1 Press the MENU key on the MEASURE screen to display the MENU screen 2 Check that the SITE SETUP is...

Страница 32: ...f PIPE PARAMETER Parameter Page No for reference Sets outer diameter of pipe P27 Sets pipe material P28 Sets pipe thickness P29 Sets kind of fluid P32 Sets sensor mounting method P34 Sets lining mater...

Страница 33: ...ase adjust Zero point turn back to SITE SETUP screen At the last line the SENSOR SPACINg value is displayed ENT Mounting dimension Install the sensor according to chapter 8 MOUNTING OF DETECTOR and th...

Страница 34: ...21 1 Move the cursor to 1 SITE MEMORY on the SITE SETUP screen Note Before setting the 2 Establish setting the Site registration is required 2 Press the ENT key to display the SITE MEMORY screen 3 Pr...

Страница 35: ...r entry screen Select a character and press the ENT key Characters will be displayed one by one in the entry field Select BS and press the ENT key to delete characters one by one In case of stoping en...

Страница 36: ...that the cursor will change to The cursor can be moved by the and the key For entering characters to the place the cursor is moved press the ESC key The cursor moves to the character entry field Note...

Страница 37: ...y after the selection to enter the outer dimension See pages 162 to 168 Piping Data Use the or key to cause the digit to move in the right and left direction Use the or key to enter the numeric After...

Страница 38: ...white to blue Press the ENT key and the PIPE MATERIAL screen will appear Select the material by the or key After entry press the ENT key When OTHERS is selected Enter the sound velocity range 1000 to...

Страница 39: ...See pages 162 to 168 Piping Data Use the or key to move the digit to the left and right Using the or key enter the numeral After entry press the ENT key B Lining thickness B A Wall thickness A Lining...

Страница 40: ...te to blue Press the ENT key the LININg MATERIAL screen will appear Select the material using the or key After selection press the ENT key When OTHERS is selected Enter the sound velocity range 1000 t...

Страница 41: ...6 Lining material Press the key the LININg THICKNESS is reversed from white to blue Press the ENT key lining thickness numeric entry can be performed The cursor can shift the numeric digit by the or k...

Страница 42: ...sound velocity Range 500 to 2500 m s Press the or key the KIND OF FLUID is reversed from white to blue Press the ENT key to display the KIND OF FLU ID screen Select the kind of fluid by the or key Aft...

Страница 43: ...C When measuring accurately or measuring fluid other than water enter as needed See page 168 Table 26 Range 0 001 10 6 to 999 999 10 6 m2 s Press the key the VISCOSITY is reversed from white to blue P...

Страница 44: ...ENSOR MOUNT is reversed from white to blue Press the ENT key The SENSOR MOUNT screen will appear Select either V or Z method by the or key Remarks Select the V method generally Use the Z method in the...

Страница 45: ...ess the key SENSOR TYPE is reversed from white to blue Press the ENT key to display the sensor type Select any sensor from the type code of sensor to be used Select the sensor by the or key ENT ENT EN...

Страница 46: ...0Vpp or 80Vpp generally If the indicator cannot be set to MAX with the level at 160Vpp ultrasonic wave may be attenuated due to contamination or scales deposited on the piping external and internal su...

Страница 47: ...point calibration ENT MENU MENU Note When the inner mounting diameter is 13mm the sensor mounting method is 0 0mm or less de pending on the pipe materials Unit mm Necessary pipe thickness for fluid w...

Страница 48: ...hat of 5D or more on the downstream side 2 No factors to disturb the flow such as pump and valve within about 30D on the upstream side L 10D Detector L 50D L 30D Flow control valve exists on upstream...

Страница 49: ...e D 1200 or more 600 or more D 600 or more 200 or more 200 or more Note 2000 or more D Pipe diameter mm Space required for mounting detector 5 The piping must completely be filled with fluid when it f...

Страница 50: ...INF TN2FSC E 41 7 Avoid mounting the detector near a deformation flange or welded part on the pipe Horizontal plane Pipe Deposits of sludge 45 45 Welded part Flange or welded Welded part...

Страница 51: ...V method Detector L Z method V method Z method Mounting method The dimension values of the sensor attachment displayed on the SITE SETTING screen of the transmitter Employ the Z method in the followi...

Страница 52: ...more FSSE should be used as much as possible for pipes such as old pipes cast iron pipes and mortar lining pipes through which it is difficult for ultrasonic signals to pass Z V FSSE FSSD V FSSH Z V Z...

Страница 53: ...te is wound on a pipe it should be peeled off before the above treatment When cast iron pipe is used grind the sensor mounting surface by using a sander for smoothness Jute is wound Detector Width Pip...

Страница 54: ...rew M4 L 6mm excessively Otherwise loose screw may come off and become lost Slide the guide rail silver Fix the rail length with fixing screw which is adjustable in every 10mm When extending the rail...

Страница 55: ...ntenance easy only if grease is used as acoustic coupler Please conduct it in the same way when removing the sensor with water proof treatment from the rail 100mm 3 937 inch 3 Loosen the lock nut and...

Страница 56: ...item 8 4 3 Method of mounting belt which vary depending on the belt type Mounting on the pipe Example Excessive turning element holder causes the rail end to come off the pipe Example Excessive turni...

Страница 57: ...e 8 4 2 How to mount a detector Z method 1 Confirm the mounting dimension in Item 7 1 2 Mark the mounting position on the pipe Please refer to Item 8 1 8 3 How to determine the mounting position 3 Pre...

Страница 58: ...the Item 4 3 for de tails 6 Connect the signal cable Note Please make sure that power of transmitter is turned OFF when connecting Connection example discriminate the cable color between the upper st...

Страница 59: ...e you may hurt yourself 1 Stainless steel belt 6th digit A 1 1 Put the belt through the hole of the rail end and wrap it around the pipe 1 3 Return the belt at the end of the latch 1 5 Lock the latch...

Страница 60: ...ut it through the buckle 3 Belt with SUS screw clamp 6th digit C 3 1 Put the belt through the hole of the rail end and wrap it around the pipe 3 3 Pull the belt lay down the screw and wrap it tighten...

Страница 61: ...t the wire length to the pipe size 4 2 Put the wire through the hole of rail end and wrap it around the pipe and hook it with mounting spring to fix Mounting spring length is approx 180mm 4 2 Put the...

Страница 62: ...the pipe by cloth belts Mounting will be facilitated by winding the cloth belts on the pipe in advance Cloth belts are usable at 80 C or lower If be yond 80 C stainless steel belts should be used High...

Страница 63: ...or Fasten the sensor unit with locknuts so that the attachment dimensions L are obtained Mounting dimension L 3 Spread siliocone grease over the whole transmitting surface of the sensor Turn the eleme...

Страница 64: ...lement holder clockwise until the sensor is firmly fitted to the piping While checking that the transmitting surface horizontally comes in contact with the pipe sur face turn the element holder until...

Страница 65: ...A 3 Mark a line along on edge of the gauge paper The intersection of this line and straight line A is replaced with A0 Draw a line along the edge A0 4 In mounting by the V method peel the gauge paper...

Страница 66: ...ion direction marks INSIDE face each other 3 Remove the two M4 screws to remove the cable clamp Put the cable and connect the signal cable Fix the signal cable with the cable clamp Cable clamp Convers...

Страница 67: ...the guide plate until its edge and transmitting surface touch the surface of pipe Then tighten the fixing screw Pipe Guide plate Fixing screw Transmission surface Transmission direction mark 2 How to...

Страница 68: ...s in the left right direction bring the sensor in close contact and fit the wire rope Align the matching mark of sensor with the marked line In addition make the transmit ting direction marks of senso...

Страница 69: ...eaning the surface of the pipe the sen sor should be mounted High temperature grease Spatula Transmission unit 3 Fix the both ends saddles of the sensor to the pipe by stainless belts Stainless belt S...

Страница 70: ...emoved sensor unit on the guide rail for high temperature sensor Fasten the sensor unit with mounting dimension L Mounting dimension L 3 Spread high temperature grease over the whole transmitting surf...

Страница 71: ...unting position is correct Then turn the element holder clockwise until the sensor is firmly fitted to the piping Stop turning the element holder where the transmitting surface contacts the surface of...

Страница 72: ...ition 1 Prepare a sheet of paper vinyl sheet of 4 D or more in length and 200 mm or longer in width D is preferable as shown below 4D Parallel 200 mm or D or larger About 100 mm 2 Draw a line intersec...

Страница 73: ...w rate is displayed when water flow stops refer to page 72 ZERO ADJUSTMENT and page 78 CUT OFF If the flow display fluctuates refer to page 76 DAMPINg Integrated flow rate value is available in the ra...

Страница 74: ...Heat quantity measurement heating operation Example For measuring heat flow refer to 10 3 3 ENERgY MODE function 4 Analog input output Display the usage state of analog input and output For using ana...

Страница 75: ...r to page 153 12 3 Er ror in measured value 10 Kind of measurement When changing the kind of measurement on the measurement screen Flow rate velocity total display can be changed on the measurement sc...

Страница 76: ...t value screen can be switched to the measurement graph screen Move the cursor to the and press the ENT key The screen switches as shown below Follow the same steps described above to return to the pr...

Страница 77: ...10 1 5 TOTAL about the totalizing function by timer operation Move the cursor to the or and press the ENT key The total process can be made in the TO TAL START Totalizing in progress STOP Not totalize...

Страница 78: ...ion settings for measurement DATA LOGGER PRINTER Various outputs on printer Saving of measured value to memory and display and output of data SYSTEM SETUP MAINTENANCE Check function of device status C...

Страница 79: ...e selection the relevant mode is deter mined 3 Select SELECTION to read out the data REgISTRATION to register the data and DELETE to delete the data SITE MEMORY allows you to register data which are s...

Страница 80: ...he ENT key So this function enables you to register the data you set Enter the name of the site Refer to 7 2 Entry of site name for details For selecting DELETE select the name of the deleted site by...

Страница 81: ...ero adjustment to be specified is carried out SET ZERO Perform zero adjustment in situation where the flow is stopped The measurement indication should be at zero when the ENT key is pressed This zero...

Страница 82: ...ft Temperature Select the unit of temperature input Metric system C K English system F K Heat flow Select the unit of heat flow and output range MJ h gJ h BTU h kBTU h MBTU h kW MW Thermal total Sele...

Страница 83: ...TN2FSC E 2 Press the or key and move the cursor to the output item of which unit to be changed 3 Press the ENT key to open the unit selection screen Select the unit by the or key and then press the E...

Страница 84: ...g output calibration and low flow rate cut off For details of output control refer to the items described in the following pages For damping refer to 1 DAMPINg when attenuating the variation of measur...

Страница 85: ...ge 0 0 to 100 0sec in 0 1 sec steps 63 Time Response time Flow rate Operation 1 Press the or key on the OUTPUT CONTROL screen and select DAMPINg Then press the ENT key and the cursor moves to the set...

Страница 86: ...cursor moves to the set item enabling you to make zero span setting 2 Press the or key to move the digit and use the or key to enter a numeric value After entry press the ENT key for setting 0 Correc...

Страница 87: ...convec tion etc even though the valve is closed this flowmeter outputs a measured value There fore values below an appropriate level should be cut off Operation 1 Press the or key on the OUTPUT CONTRO...

Страница 88: ...Move the cursor to START by the or key and then press the ENT key The total will start 2 Pressing the ENT key enables you to select the total output mode Select the mode from MANUAL FIXED TIME and TIM...

Страница 89: ...E mode Total starts after the time of set ting total is performed within the time selected from the menu and it stops automatically after the time passed 30min 1hour 1hour 30min 2hour 2hour 30min 3hou...

Страница 90: ...table range 0 000 to 9999999999 Resetting actual integral values should be performed on the measurement screen See Page 65 ERROR TOTAL Determines how to dispose of the total when the measurement statu...

Страница 91: ...d measurement data make the setting on graph display and print output Saved logger data The green displays under logging Site name Up to 100 items can be viewed by using the cursor For 100 or more che...

Страница 92: ...tarted or when quick logger stop button is pressed Logging time 1 hour fixed Cycle 10 seconds fixed Measured data type 3 types unit and number of digits after decimal point are the same dis played in...

Страница 93: ...e exit time logging is performed over 0 o clock Logging period Start date to exit date Logging time Start time to end time Period 10 seconds to 23 hours Measured data type 14 measured data types and s...

Страница 94: ...ans logger start time and relevant logger data files Data file Logging name _ date _ hour csv Logging data in a specific period The maximum number of data files in a logger is 20 files in case of a CO...

Страница 95: ...the steps 2 to 8 given shown below 3 Register the place or the pipe name for logging Refer to Page 24 and 25 to enter characters 2 Register the name of the logger Press the ENT key after the cursor i...

Страница 96: ...eration mode Move the cursor pointed from KIND to MODE by the key 6 After selection return the cursor to KIND by the ESC key 8 Press the ENT key and the cursor moves to CON TINUOUS Then press the key...

Страница 97: ...selected Totalizer action is not enable when conducting the start of logging Be sure to make a setting of Totalizer action according to Item 10 1 5 in this manual In case heat mode is NOT USED it is...

Страница 98: ...the LOggER DATA screen appears press the ENT key Note Logger data will be stored at the selected site name in the Site Memory Thus when you select the different site name to see the logger data that...

Страница 99: ...ly types of logged data 6 To change scale of time axis horizontal axis and data axis vertical axis Move the cursor to ZOOM to enlarge or contract the time axis by the or key Enlarge or contract the da...

Страница 100: ...logger data Kind of data source Unit of printing data Cursor Time Data 7 For moving time axis Press or key move the cursor to SCROLL and then press the ENT key SCROLL will be read ied For moving time...

Страница 101: ...ress the ENT key 2 When the LOggER DATA screen appears press the ENT key 3 The MODE screen appears Select PRINT and press the ENT key 4 Press the or key to select the name of logger data No and press...

Страница 102: ...ess Change to 7 by the or keys ENT 2 Select STOP DATA POSI and press Change to 361 by the or keys ENT 3 Select CYCLE and press Change to 00 10 00 by the or keys ENT 4 Select PRINT and press and printi...

Страница 103: ...ey and press the ENT key YYYY Year MM Month DD Day 10 3 Setting of system SYSTEM SETUP screen This system allows you to accomplish the BASIC SETUP system setup such as setup of clock and measurement u...

Страница 104: ...the or key and enter numeric values by the or key After entry press the ENT key The setup time is set at this point Setup contents 2008 02 01 10 03 year month day hour minute When using the total or t...

Страница 105: ...m selection of meter system and inch system Operation 1 Select SYSTEM UNIT by the or key on the BASIC SETUP screen Press the ENT key and the SYSTEM UNIT screen is displayed 2 Select METRIC or ENgLISH...

Страница 106: ...LCD will be OFF If key operation is performed while the backlight is kept off it comes on If 0 min is selected for OFF time the light is kept ON LCD ON LCD POWER OFF 2 Key operation LCD POWER OFF 2 L...

Страница 107: ...to the PRINTER SD MEMORY Save the screen copy data to the SD MEMORY Operation 1 Press the or key on the BASIC SETUP screen and select DEFINITION OF PRINT KEY Press the ENT key to open the DEFINITION O...

Страница 108: ...is possible Operation 1 Press the or key on the BASIC SETUP screen and select MEASURE METHOD Press the ENT key and the screen appears prompting you to select measurement method The measurement method...

Страница 109: ...a will be retained 1 The site that has been not selected site memory 2 Clock 3 Analog output input calibration value 4 The contents of SD memory card CAUTION 2 Select REBOOT by pressing the or key and...

Страница 110: ...you to set the analog input output and perform input output calibration AI ch2 AO AI ch1 Red Red Black Black 4 to 20mA AO Output Indicator recorder regulator etc Note The connector should be connecte...

Страница 111: ...ration 1 Press the ENT key on the SETTINg screen and move the cursor to ANALOg INPUT OUTPUT Press the ENT key and the screen appears prompting you to decide whether analog input output is used or not...

Страница 112: ...d Voltage input Connect the external flow transmission of 1 to 5V DC Definition of Analog input2 NOT USED select this when you do not use Current input APPLICATION Connect the external flow transmitte...

Страница 113: ...cursor to the INPUT on the SETTINg screen by pressing the or key and display the INPUT screen Press the ENT key and the cursor moves to CH1 INPUT CALIBRATION or CH2 INPUT CALI BRATION Select CH1 INPUT...

Страница 114: ...calibration After calibration the End of Calibration message appears under the calibration button Analog input has already been calibrated on the factory setting When you interrupt the calibration in...

Страница 115: ...moves to CH1 INPUT CALIBRATION Select CH1 INPUT CALIBRATION by the or key and press the ENT key Select the kind of input you set on the SETTINg screen by the or key and press the ENT key The cursor mo...

Страница 116: ...ibration After calibration the End of Calibration message appears under the calibration button Analog input has already been calibrated on the factory setting When you interrupt the calibration in the...

Страница 117: ...he cursor moves to 4 mA 2 Select either 4 mA or 20 mA by the or and press the ENT key Adjust the output circuit so that outputs are adjusted to either 4 mA 0 output calibration or 20 mA 100 output cal...

Страница 118: ...DE screen Heat source Load Detector type FSS Converter Converter Q Flow rate of the heating medium T2 Temperature of the heating medium of the receiving side T1 Fluid temperature inlet Flowmeter Type...

Страница 119: ...l be disabled When you select TEMPERATURE SETTINg the temperature you entered is set to feeding temperature Setting range 40 to 240 C MODE Select the ENERgY MODE When you select NOT USED calo rie is n...

Страница 120: ...RETURN TEMP When you select TEMPERATURE SETTINg the entered temperature is set to returning temperature Setting range 20 to 120 C Note1 To set the feed return temperature to the fixed temperature TMPE...

Страница 121: ...t conversion Full scale 20mA or 5V Base scale 4mA or 1V Input conversion Input 100 Full scale Base scale Base scale 1 Press the or key on the RANgE screen to select INPUT RANgE Press the ENT key to di...

Страница 122: ...INF TN2FSC E 113 4 Move the cursor to FULL SCALE by the or key and set the full scale in the same manner as the base scale...

Страница 123: ...ut range Select the kind of output range by the or key and press the ENT key For the thermal flow of the range kind make 10 3 3clause of ENERgY MODE USED and use it 100 Flow rate Forward Reverse Analo...

Страница 124: ...nner as the output limit low 3 Set the range type single range or bi directional range Select RANgE TYPE by pressing the or key 4 Press the ENT key to display the RANgE TYPE screen Select the range ty...

Страница 125: ...or key and press the ENT key 2 ERROR setting of analog output at error Burnout When an error occurs set a current output to force a set value When resolving the cause the current output is automatical...

Страница 126: ...to set the time 5 Move the digit by the or key and enter numeric values by pressing the or key After entry press the ENT key HOLD Holds output indications before the occurrence of errors UPPER 10 4 2...

Страница 127: ...TER 10 5 1 Selection of printing mode 1 Select any of the modes of TEXT gRAPH and LIST on the PRINTER screen by the or key Press the ENT key to switch the printing mode setting screen For the meaning...

Страница 128: ...Printing of text Printing of graph Test print Example of printing list Print cycle 10 5 2 Example of printing Measurement condition Selected type Glancing piling interval Flow rate total X axis Y axis...

Страница 129: ...tems are selectable simul taneously 1 When the cursor is pointed to KIND on the PRINT OF TEXT screen press the ENT key to select the item to be printed as text data Press the or key to select the item...

Страница 130: ...select the item for which graph is to be printed Press the or key and press the ENT key After selecting the item return the cursor to KIND by the ESC key 2 Move the cursor to SCALE by the or key Pres...

Страница 131: ...ed setting will be printed 2 Move the cursor to START and press the ENT key to start printing 10 5 6 STATUS DISPLAY It allows you to display the printer status and perform the printing test Content of...

Страница 132: ...it time 1 When an error is detected on measurement screen 1 Move the cursor to 1 TRANSIT TIME on the MAINTENANCE screen and press the ENT key The TRANSIT TIME SIgNAL CHECK screen is displayed 2 Move t...

Страница 133: ...ENT key and the TRANSIT TIME SIgNAL CHECK screen is dis played 2 Move the cursor to SOURCE on the TRANSIT TIME SIgNAL CHECK screen and press the ENT key 4 When SOURCE is selected SIgNAL CHECK dis play...

Страница 134: ...e cursor to SCROLL and then press ENT key SCROLL will be readied For movement of time axis press the or key 7 For adjusting the time axis migration Point the cursor to CURSOR and press the ENT key to...

Страница 135: ...ger level Displays the detection level of received waveform Signal peek Displays the peak value of received waveform Normal values stably fall within the range from 5528 to 6758 If the value fluctuate...

Страница 136: ...transmission voltage and perform measurement See page 36 3 No received signal The waveform is free of the received waveform and this is the waveform to which the noise is expanded The equipment cannot...

Страница 137: ...mA or the voltage input is 1 5V it is possible to check for the input status 1 Move the cursor to CHECK on the MAINTENANCE screen and press the ENT key to display the CHECK screen 2 Check for the curr...

Страница 138: ...using the test mode to check for the measure ment status move the cursor pointed to ANALOg OUTPUT to TEST MODE and make the following settings TEST MODE USED NOT USED INPUT DATA Simulated flow rate t...

Страница 139: ...y of data screen Flow profile Display of file name only 1 Move the cursor to SD MEMORY CARD on the MAINTE screen and press the ENT key to display the SD MEMORY CARD screen 2 Press the ENT key on the S...

Страница 140: ...ack to the selection screen press the ESC key 2 To check for print screen data 1 When PRINT SCREEN is selected on the SD MEMORY CARD screen the screen appears prompting you to select the dump data Mov...

Страница 141: ...r data appears move the cursor to the logger data which you want to delete by the or key 2 Move the cursor to the logger data you want to delete press the or key The message on the right side will be...

Страница 142: ...ls of the liquid crystal display by displaying 16 colors in the horizontal stripes There is a possibility that surface irregularity occurs in the brightness due to characteristics of liquid crystal di...

Страница 143: ...check and software update are permitted Version Update 1 In order to check the version Move the cursor to Software in the maintenance screen and press the ENT key Transition to the software screen ap...

Страница 144: ...smitter and perform electric supply 3 Turn the power ON by pressing the ON switch on the main unit 4 Press the ENT key on the software screen of the MAINTENANCE screen A message appears 1 If update is...

Страница 145: ...ameter 100 to 400mm Fluid temperature 40 to 80 C FSDP0 Bore diameter 200 to 1000mm Fluid temperature 40 to 80 C 10 7 1 Installing Detector 1 Processing of detector mounting surface Remove rust pitch s...

Страница 146: ...e absorb er unit that are to contact the pipe Absorber unit Sensor unit G re a s e 4 Fasten the sensor with the belt checking the flow direction FSDP2 FSDP1 FSDP2 FSDP0 Flow direction Flow direction 5...

Страница 147: ...th tape not to allow deviation At this time the edge of gauge paper should be aligned 1 Extending the line marked on the gauge paper mark straight line A on the pipe 2 Mark a line along on edge of the...

Страница 148: ...ixes the wire on the pipe FSDP0 2 Fully screw up to the right side Screw 3 Before mounting the sensor to the pipe apply grease evenly over the sensor unit and the ab sorber unit that are to contact th...

Страница 149: ...de attach the sensor firmly to the pipe Screw 5 Connect the detector and the converter unit Connect the sensor unit and the converter unit with the signal cable For 1 path connect them on the upstream...

Страница 150: ...27 Material Page 28 Thickness Page 29 Lining material Page 30 Thickness Page 31 Fluid kind Page 32 Transmission voltage Page 36 Note For metal pipes raise the transmission voltage to 160Vp p 2 Press M...

Страница 151: ...ow velocity distribution begins upon selection of a source Dumping The flow velocity distribution is displayed as averaged Instantaneous data is displayed if 0 display is set Cursor Move the cursor us...

Страница 152: ...ng the key and press the ENT key Set connection between the sensor and conversion unit s connector Use the upstream side normally in case one measur ing line Sensor U In case of two measuring lines us...

Страница 153: ...int the cursor to MEAS RANgE by using the key and press the ENT key Select the range of flow velocity distribution to be measured Radius F Measurement is taken on the radius side opposite to the senso...

Страница 154: ...inless steel is selected as pipe material nominal wall thickness is Sch20s and the fluid is water the following chart displays the measurable range in above condition Maximum measurable flow velocity...

Страница 155: ...ons in accordance with countermeasures against display con tents and 12 ERROR AND REMEDY 10 8 1 How to check status display 1 For checking an error in the measurement screen Move the cursor to the sta...

Страница 156: ...de E1 Display the instrument abnormality 1 E1 Device error 1 2 E1 Device error 2 2 Error code E2 Display the flow rate abnormality 1 E2 Windows scan 2 E2 No received signal 3 E2 Received signal error...

Страница 157: ...FSC E 3 Error code E3 Display the flow velocity profile measurement 1 E3 Measurement range error 2 E3 Frequency calculation error 3 E3 Success rate 4 Error code E4 Display the analog output error 1 E4...

Страница 158: ...INF TN2FSC E 149 5 Error code E5 Display the analog printer error 1 E6 Printer fail...

Страница 159: ...d FSSD 3 Replacement of clock backup battery In normal usage the battery has a service life of about 10 years The service life may change depending on the operating environment and condition When the...

Страница 160: ...opportunity Regardless of the time period of the occurrence Fuji Electric is not liable for the damage caused by the factors Fuji Electric is not responsible for opportunity loss of the purchaser cau...

Страница 161: ...2 Connector on both sides ZZP TK7N7795C1 8 Extension signal cable Special type coaxial cable with BNC connector 10m 2 50m 2 ZZP TK468664C3 ZZP TK468664C4 9 Analog input output cable 6 core cable 1 5m...

Страница 162: ...isplay is not clear Entire display is blackish Hardware error Ambient temperature is high 50 C or higher LCD has reached the end of its service life Lower the temperature Replace the LCD Ambient tempe...

Страница 163: ...value remains the same though flow rate is changing Measured value is held because ultrasonic wave cannot be propagated into a pipe 1 Incomplete installation Piping specifications are wrong Sensor is...

Страница 164: ...n the same line where the outer diameter of pipe is smaller Move to a different place or different pipe Raise the voltage for trans mission refer to p 36 Because of an old pipe scale has stuck to the...

Страница 165: ...ngth of straight pipe portion is inadequate Select a different location of sensor mounting move the up stream side of a flow disturbing element 10D and 5D are required at least on the upstream and dow...

Страница 166: ...alog output is not adjusted properly Calibrate analog output Output rises beyond 20mA Indication value is larger than analog span value Span is deviated Overshoot Set analog span again Calibrate analo...

Страница 167: ...o back None Flow control Xon off 2 Interface specification Electrical specification Conforms to USB standard Cable length 3 m or less Conforming cable Mini USB cable Connection scheme 1 1 connection S...

Страница 168: ...HOW TO USE PRINTER 14 1 How to connect printer 1 Turn off the power supply of main unit 2 Remove the rubber guards 3 Detach the top cover of main unit 4 Attach the printer Connect the printer cord Fr...

Страница 169: ...C E 5 Install the printer with 2 screws 6 Install the rubber guards Note Install it so that the groove of the rubber guards may fit tightly on the edges of the main unit 7 Turn ON the power supply of...

Страница 170: ...f roll paper into the head assembly Cut the edge of the recording paper so that central part of it can be inserted first Insert the paper straight to the paper insertion section 3 For feed paper use F...

Страница 171: ...1 Turn off the power supply of main unit 2 Remove the rubber guard 3 Remove 4 screws on the back 4 Remove the battery 1 Take battery cover off 2 Turn the display up while holding the bottom of the uni...

Страница 172: ...not use the equipment with the built in battery removed CAUTION 5 Insert the battery packs Note Make sure to match the terminals of the batteries to those of the unit 1 Insert the first battery 2 Ins...

Страница 173: ...9 5 12 7 15 9 150 6 165 2 2 8 3 4 5 0 7 1 11 0 14 3 18 2 200 8 216 3 2 8 4 0 6 5 8 2 12 7 18 2 23 0 250 10 267 4 3 4 4 0 6 5 9 3 15 1 21 4 28 6 300 12 318 5 4 0 4 5 6 5 10 3 17 4 25 4 33 3 350 14 355...

Страница 174: ...0 118 0 150 9 5 9 0 169 0 200 10 0 9 4 220 0 250 10 8 9 8 271 6 300 11 4 10 2 322 8 350 12 0 10 6 374 0 400 12 8 11 0 425 6 450 13 4 11 5 476 8 500 14 0 12 0 528 0 600 15 4 13 0 630 8 700 16 5 13 8 73...

Страница 175: ...nal thickness STW 290 STW 370 A B Nominal diameter A Outer diameter mm Thickness mm Thickness mm Thickness mm Thickness mm 11 Centrifugal nodular graphite cast iron pipe for city water A type JWWA G 1...

Страница 176: ...5 17 5 650 26 660 4 5 5 8 0 12 7 700 28 711 2 5 5 8 0 12 7 750 30 762 0 6 5 8 0 12 7 800 32 812 8 8 0 12 7 850 34 863 6 8 0 12 7 900 36 914 4 8 0 12 7 1000 40 1016 0 9 5 14 3 16 Dimensions of centrifu...

Страница 177: ...44 1117 6 260 281 303 324 346 357 411 432 1200 48 1219 2 283 307 331 354 378 390 448 472 1350 54 1371 6 399 426 439 505 532 1500 60 1524 0 444 473 488 562 591 1600 64 1625 6 521 600 631 1800 72 1828...

Страница 178: ...0 63 2 5 3 0 75 2 5 3 6 90 2 8 4 3 110 3 4 5 3 125 3 9 6 0 140 4 3 6 7 160 4 9 7 7 180 5 5 8 6 200 6 2 9 6 225 6 9 10 8 250 7 7 11 9 280 8 6 13 4 315 9 7 15 0 355 10 8 400 12 2 450 13 7 Nominal diame...

Страница 179: ...82 87 1552 37 88 89 90 91 92 93 94 95 96 97 98 99 100 1551 88 1551 35 1550 79 1550 20 1549 58 1548 92 1548 23 1547 50 1546 75 1545 96 1545 14 1544 29 1543 41 Note T temperature V velocity of sound Al...

Страница 180: ...easurement kind Scale Status display Selection Registration Delete Zero adjustment Unit of output Output control Totalize Logger data Logging Outer Diameter Pipe material Pipe thickness Lining Materia...

Страница 181: ...ration Flux measurement Feeding temperature Returning temperature Received Signal Measurement data Logger data Print screen Flow profile Analog input Analog output Version Update Print of text Print o...

Страница 182: ...300mm 2 to 32m s 1 0 to 1 5 of rate 0 to 2m s 0 02 to 0 03m s 300 to 6000mm 2 to 32m s 1 0 to 1 5 of rate 0 to 2m s 0 02 to 0 03m s Note Reference conditions are based on JEMIS 032 Flow transmitter T...

Страница 183: ...Printer option To be mounted on top of transmitter unit Thermal line dot printing Note For selecting Chinese the printing character will be Japanese Kanji character Ambient temperature 10 to 55 C Wit...

Страница 184: ...ction Fluid temperature be displayed by current input from temperature transmitter Metric system Temperature unit C or K English system Temperature unit F or K Site data storage function Max 32 locati...

Страница 185: ...or Ambient temperature 20 to 60 C Ambient humidity FSSE 100 RH or less Other 90 RH or less Type of enclosure FSSC IP65 When waterproof BNC connector is provided FSSE IP67 Others IP52 Material of detec...

Страница 186: ...flow in a filled pipe Fluid temperature 40 to 100 C FSDP2 40 to 80 C FSDP1 FSDP1 Air bubble quantity 0 02 to 15Vol Velocity is 1m s Pipe size Small type sensor 40 to 200mm Middle type sensor 100 to 4...

Страница 187: ...rea due to scaling will become an error Therefore the flow indicated is a little larger than the actual flow When the scale thickness is known it can be compensated by adding it to the lining thicknes...

Страница 188: ...alue of the mixing amount of air bubbles III Q A about measuring conditions at locations 1 What about mounting the sensor on horizontal piping The sensor should be mounted in the horizontal direc tion...

Страница 189: ...n the value set for piping size is different from the actual size of piping and if the difference from the inside diameter is about 1 in size the error is about 3 of deviation obtained by flow convers...

Страница 190: ...ltrasonic flowmeter indicates volume flow containing air bubbles 3 What about comparison with other flowmeters Although thermometers and pressure gauges can easily be calibrated at a site flowmeters a...

Страница 191: ...eet is fed at 0 125 mm dot Setting the paper feed at a cycle of 1 second uses a roll of paper in 224 000 sec about 62 2 hours 28 m 0 125 mm 2 In case of TEXT mode A single printing consists of the fol...

Страница 192: ...CHANNEL 2 AI CHANNEL 2 Yes 10 places 3 places SUPPLY TEMP SUPPLY TEMP Yes 3 places 3 places Temperature unit RETURN TEMP RETURN TEMP Yes 3 places 3 places Temperature unit TEMP DEFFERENCE TEMP DEFFER...

Страница 193: ...drop during acquisi tion FIFO EMPTY No vacancy in measurement FIFO ABNORMAL Stop caused by system error during acquisition SIZE Byte size of target data file SUM Total number of data up to target data...

Страница 194: ...quent Units of logged types for the quantity ASCII characters show units Line 3 and subsequent A Date and hour Line 3 and subsequent B and subsequent Date hour name measured data and RAS 32 bit binary...

Страница 195: ...on date hour in the 2007 10 29 10 19 44 format Line 5 and subsequent A Describes Velocity Profile The measurement data C to IU Fluid velocity that corresponds to channel number in line 2 IU Flow rate...

Страница 196: ...ales Section Instrumentation Sensors Planning Dept 1 Fuji machi Hino city Tokyo 191 8502 Japan http www fujielectric com Phone 81 42 514 8930 Fax 81 42 583 8275 http www fujielectric com products inst...