5-14
(H codes continued)
Code
Name
Data setting range
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer
to
page:
H50
Non-linear V/f Pattern 1
(Frequency)
0.0 (Cancel), 0.1 to 400.0
0.1
Hz
N
Y
0.0
5-23
H51
(Voltage) 0 to 240: Output an AVR-controlled voltage
(Note 1)
1
V
N
Y2
ACE:0
U:230/
460
0 to 500: Output an AVR-controlled voltage
(Note 2)
H52
Non-linear V/f Pattern 2
(Frequency)
0.0 (Cancel), 0.1 to 400.0
0.1
Hz
N
Y
0.0
H53
(Voltage) 0 to 240: Output an AVR-controlled voltage
(Note 1)
1
V
N
Y2
0
0 to 500: Output an AVR-controlled voltage
(Note 2)
H54
ACC/DEC Time
(Jogging operation)
0.00 to 3600
0.01
s
Y
Y
6.00
–
H61
UP
/
DOWN
Control
0: 0.00
–
–
N
Y
1
(Initial frequency setting) 1: Last
UP
/
DOWN
command value on
releasing a run command
H63
Low Limiter
(Mode selection)
0: Limit by F16 (Frequency limiter: Low)
and continue to run
–
–
Y
Y
0
5-35
1: If the output frequency lowers below the
one limited by F16 (Frequency limiter:
Low), decelerate to stop the motor.
H64
(Lower limiting
frequency)
0.0 (Depends on F16 (Frequency limiter:
Low))
0.1 to 60.0
0.1
Hz
Y
Y
2.0
–
H69
Automatic Deceleration
(Anti-regenerative
control)
0: Disable
1: Enable (Lengthen the deceleration time
to three times the specified time under
voltage limiting control.) (Compatible with
the original FRENIC-Mini series
FRN
C1
-
)
–
–
Y
Y
0
5-74
(Mode selection) 2: Enable (Torque limit control: Cancel the
anti-regenerative control if the actual
deceleration time exceeds three times
the specified one.)
4: Enable (Torque limit control: Disable
force-to-stop processing.)
H70
Overload Prevention
Control
0.00: Follow deceleration time specified by
F08/E11
0.01 to 100.0, 999 (Cancel)
0.01 Hz/s
Y
Y
999
5-75
H71
Deceleration
Characteristics
0: Disable
1: Enable
–
–
Y
Y
0
H76
Automatic Deceleration
(Frequency increment
limit for braking)
0.0 to 400.0
0.1
Hz
Y
Y
5.0
5-74
H78
Maintenance Interval *1
0: Disable,
1 to 9999 (in units of 10 hours)
1
–
Y
N
8760
–
H79
Preset Startup Count for
Maintenance *1
0000: Disable,
0001 to FFFF (hex.)
1
–
Y
N
0000
H80
Output Current
Fluctuation Damping
Gain for Motor 1
0.00 to 0.40
0.01
–
Y
Y
0.20
*1 Available in the ROM version 0500 or later.
(Note 1)
For the three-phase / single-phase 200 V and single-phase 100 V class series
(Note 2)
For the three-phase 400 V class series