Signal SNR report:
$QOS,Q1,Q2*CSUM<CR><LF>
$QOS:
The keyword sent on the beginning of each quality of signal report.
Q1:
Quality of signal estimate based on sensor vibration.
Q2:
Quality of signal estimate signal quality.
CSUM:
The check sum of the characters in the report from $ to * excluding these
characters
Quality of signal factor:
0 – Excellent measurement quality
1 – Good measurement quality
2 – Low measurement quality
3 – Unacceptable measurement quality
Water level report:
$LVL,L1,L2,T1,L3,L4,S*CSUM<CR><LF>
$LVL:
The keyword sent on the beginning of each level report.
L1:
Current distance from sensor to water, in defined units, 0 being sensor
reference plane. If reporting -4 then there is no detected level.
L2:
Average distance from sensor to water, in defined units, 0 being sensor
reference plane. If reporting -4 then there is no detected level.
T1:
Electronic temperature (in °C).
L3:
Current relative detected level, in defined units, 0 being sensor reference
plane.
L4:
Average relative detected level, in defined units, 0 being sensor reference
plane.
S:
Measurement SNR (in dBm).
CSUM:
The check sum of the characters in the report from $ to * excluding these
characters.
Discharge report:
$DIS,D*CSUM<CR><LF>
$DIS:
The keyword sent on the beginning of each discharge report.
D:
The measured discharge, in defined units.
CSUM:
The check sum of the characters in the report from $ to * excluding these
characters.