Finally, one or more correction coefficients that define the ratio between the surface
velocity and average velocity need to be defined in k-coefficients table. This is done
through the “Discharge parameters”. Select “Add k-factor” and insert the information.
Multiple values can be defined for different water levels.
5)
Once on site, mount the radar and adjust the Radar X and Y offset to accurately reflect
the position on the entered profile. Then use the Staff Gauge Reading button to enter
the current water level as reported on the site’s staff gauge.
NOTE: This will not affect the discharge calculations and this can also be done using the
SDI-12 Set Current Staff Gauge Reading X command (f!).