3–6
3.6 Programming the FGP55 CM-III.5 Computer (cont.)
NOTE 2:
The unit comes from the factory configured to display in degrees Fahrenheit. To
toggle back and forth between Fahrenheit and Celsius, press the
switch, then enter the code
1 6 5 8
by pressing the corresponding product buttons. Next, press the
switch to lock in
the new display option.
3. Enter the number
1 6 5 0
by pressing the corresponding product buttons. The computer
cannot be programmed unless this code is entered, thus preventing any unauthorized changes to
current program instructions.
4.
(Setpoint) will appear in the left LED display. Any previously programmed temperature
setpoint will appear in the right display. To change the setpoint, enter the desired setpoint
temperature using the corresponding product buttons. The setpoint can be programmed for any
value up to 212
°
F (100
°
C). Press the Program Mode
switch to lock in the new setpoint (or
the old setpoint, if it was not changed).
5.
(Select Product) will appear in the left display. Press the product button to be
programmed (or press
to return to the normal operating mode).
6.
(Rethermalizing Time) will now show in the left display. Any previously programmed
rethermalizing time will appear in the right display. Pressing
will accept the current
rethermalizing time. To change the rethermalizing time, enter the new time using the product
buttons. The rethermalizing time can be programmed up to 59:59. Press
to lock in the new
time.
NOTE: The computer can be programmed for either "standard" or "slow" clock. The standard
clock displays minutes and seconds, the slow clock displays hours and minutes. To toggle
between times press the
switch, then enter the code
1 6 5 3
using the product buttons.
Press the
switch to lock in the clock speed. To determine whether the clock speed is set to
standard or slow, initiate a rethermalizing cycle by pressing a product button. If the computer is
set to the standard clock, the time in the LED display will immediately begin to count down. If
countdown does not begin immediately, the computer is set to the slow clock.
7.
SH1
(Stir Time 1) appears in the left display. If your product requires stirring during the
rethermalizing process, set the number of seconds to heat before stirring using the product
buttons. If your product does not require stirring, enter "0". The number entered will appear in
the right display. The stir time can be programmed up to 59:59,
but must not exceed the
product rethermalizing time
. Press
to lock in the programmed time.
For example, entering "30" means the product needs to be stirred after it has been rethermalizing
for thirty seconds. At the end of thirty seconds, an alarm will sound and the product switch will
flash until cancelled by the operator pressing the product button.
Содержание Rethermalizer FGP55