66
A11
Process active
0
1
Power source not active
Power source delivering power
(open circuit voltage or welding power)
A12
Arc stable
0
1
Welding current < 5 A or
welding voltage < 10 V
Welding current > 5 A and
welding voltage > 10 V
A13
Not used
A14
Power source ready
0
1
Power source not ready => see "Trouble-
shooting" section
Power source ready
A15
Communication ready
0
1
No communication between KL6021 and
power source
Communication between KL6021 and pow-
er source OK
A16
Not used
A17 - A32
Not used
Voltage actual value
A33 - A40
High Byte
Value of actual welding or open circuit volt-
age in 0.1 V steps
A41 - A48
Low Byte
Current actual value
A49 - A56
High Byte
Value of actual welding current in 0.1 A
steps
A57 - A64
Low Byte
A65 - A112 Not used
A113 -
A224
Same signal assignment as
A01 - A112 for power
source no. 2
A225 -
A336
Same signal assignment as
A01 - A112 for power
source no. 3
.
:
:
A785 -
A896
Same signal assignment as
A01 - A112 for power
source no. 8
Seq. no.
Signal designation
Signal description