69
EN
Earth current
(earth current watchdog option only)
7
Indicators shown on the right light up, interface indicator flashes red
Cause:
Current flowing via device earth
Remedy:
-
Check ground earth connection to the workpiece
-
Switch device off and back on again
-
Fault keeps recurring => have device serviced
Mains undervoltage or overvoltage
8
Indicators shown on the right light up, interface indicator flashes red
Cause:
The mains voltage is outside the tolerance range
Remedy:
-
Check the mains voltage
-
Switch device off and back on again
-
Fault keeps recurring => have device serviced
Open circuit
9
Indicators shown on the right light up, interface indicator flashes red
Cause:
Output voltage is greater than 113 V
Remedy:
Switch machine off and on again;
if fault keeps recurring, have device serviced
Working voltage
11
Indicators shown on the right light up, interface indicator flashes red
Cause:
Working voltage >45 V and >2 seconds
Remedy:
Remove start signal =>
=> Check process =>
=> Set start signal again
Overtemperature
B
16
Overtemperature indicator lights up, interface indicator flashes red
Cause:
Power source exceeded max. temperature
Remedy:
Wait until the device has cooled down
Acknowledges automatically after cooling down
No communication
150
Interface indicator flashes red
Cause:
No communication
Remedy:
Check interface cable
Acknowledges automatically when communication is es-
tablished
Description
Indicator
No.
A
D
C
B
A
D
C
B
A
D
C
B
A
D
C
B
Interface