The power source is fitted with an intelligent safety system that allows fuses to be dis-
pensed with entirely. After a possible malfunction or error has been remedied, the power
source can be put back into normal operation again without any fuses having to be re-
placed.
Safety
Fault diagnosis
Power source has no function
Mains switch is on, but indicators are not lit up
Cause:
There is a break in the mains lead; the mains plug is not plugged in
Remedy:
Check the mains lead, ensure that the mains plug is plugged in
Cause:
Mains socket or mains plug faulty
Remedy:
Replace faulty parts
Cause:
Mains fuse protection
Remedy:
Change the mains fuse protection
No welding current
Mains switch is ON, overtemperature indicator is lit up
Cause:
Overload
Remedy:
Check duty cycle
Cause:
Thermostatic safety cut-out has tripped
Remedy:
Wait until the power source automatically comes back on at the end of the
cooling phase
Cause:
Insufficient cooling air intake
Remedy:
Ensure adequate air supply
Cause:
Power module very dirty
Remedy:
Clean device using dry compressed air (see "Care and maintenance")
Cause:
The fan in the power source is faulty
Remedy:
Have device serviced
WARNING!
An electric shock can be fatal. Before opening the device
-
Turn the mains switch to the "O" position
-
Unplug the machine from the mains
-
Prevent it from being switched on again
-
Using a suitable measuring instrument, check to make sure that electrically
charged components (e.g. capacitors) have discharged
CAUTION!
Inadequate PE conductor connections can cause serious injury and
damage. The housing screws provide a suitable PE conductor connection for
earthing (grounding) the housing and must NOT be replaced by any other screws
which do not provide a reliable PE conductor connection.