71
EN
Technical data
TP 3500 CC Re-
mote
1)
connected to public grid at 230/400 V and 50 Hz
2)
d.c. = Duty cycle
ROB TSt interface
Mains voltage
3 x 200 | 230 | 240 | 380 | 400 | 460 V
Mains voltage tolerance
+/- 10 %
Mains frequency
50/60 Hz
Mains fuse protection
32 A slow-blow
Primary cont. power (100% duty cycle)
12,2 kVA
Mains connection
1)
Restrictions possible
Primary continuous current
at 220 A / 28,8 V secondary
28,2 | 25,4 | 24,5 | 17,5 | 16,8 | 15,0 A
No load power
109 | 130 | 140 | 289 | 315 | 410 VA
Cos phi
at 350 A
0.99
Efficiency
at 220 A / 28,8 V
87 %
at 150 A / 40,0 V
89 %
Welding current range
10 - 350 A
Welding power at
10 min / 40 °C (104 °F)
35 % d.c.
2)
350 A / 34,0 V
10 min / 40 °C (104 °F)
60 % d.c.
2)
280 A / 31,2 V
10 min / 40 °C (104 °F) 100 % d.c.
2)
220 A / 28,8 V
10 min / 40 °C (104 °F) 100 % d.c.
2)
150 A / 40,0 V
Apparent power at
10 min / 40 °C (104 °F)
35 % d.c.
2)
19,9 kVA
10 min / 40 °C (104 °F)
60 % d.c.
2)
15,5 kVA
10 min / 40 °C (104 °F) 100 % d.c.
2)
11,3 kVA
10 min / 40 °C (104 °F) 100 % d.c.
2)
11,0 kVA
Max. welding voltage at 350 A
40,7 | 47,2 | 47,3 | 40,8 | 43,1 | 47,2 V
Open circuit voltage
89 V
Degree of protection
IP 23
Type of cooling
AF
Insulation class
B
Marks of conformity
CE
Safety symbols
S
Dimensions l x w x h
500 x 190 x 380 mm
19.68 x 7.48 x 14.96 in.
Weight
20,1 kg (44.3 lb.)
Overvoltage category
III
Pollution level according to IEC60664
3
Ventilation capacity
approx. 6 m³ / minute
Marks of conformity
CE
Dimensions l x w x h
160 x 90 x 58 mm
Weight
1.05 kg
Содержание TransPocket 3500
Страница 2: ...0...
Страница 4: ...2...
Страница 40: ...38...
Страница 74: ...72...
Страница 75: ...Appendix...
Страница 78: ...76 Circuit diagram TransPocket 3500 CC Remote...
Страница 79: ...77...