40
Maintenance
work every 1000
operating hours
Maintenance must be performed every 1000 operating hours, or earlier if operating condi-
tions dictate (e.g. dusty environment). The maintenance operations are carried out by au-
thorised service technicians and are designed to preserve
-
the satisfactory condition of the device
-
its performance
-
the warranty requirements
Service life
WARNING!
Exceeding the service life of high pressure vessel and tank valve can cause serious
injury and damage.
The high pressure vessel has a service life of 10 years or 11250 full cycles. A warning mas-
sage appears on the control panel of the device before reaching the end of the service life.
Exceeding the service life can effect the safety of the vessel and may cause serious dam-
age.
The tank valve has a service life of 50000 switching cycles. A warning message appears
on the control panel of the unit before reaching the end of the service life. Exceeding the
service life can effect the safety of the tank valve and may lead to faulty closing behaviour
and leakage of the valve.
WARNING!
Danger of serious injury and damage if the required maintenance measures and
safety tests are not carried out properly.
The operator is responsible for the safe operation of the device with all maintenance meas-
ures and safety checks. If the service life of the components is exceeded, the device must
be taken out of service. In the event of non-compliance with these conditions, the manu-
facturer does not ensure any safety of the device.
Pressure equip-
ment
The device contains a pressure bottle as well as other high pressure components. The ap-
plicable national and regional regulations must be observed for their operation. The year
of production of the high-pressure vessel can be taken from the rating plate of the unit. De-
tailed information on installed components can be found in the attached documents.
Disposal
Dispose of in accordance with the applicable national and local regulations.