32
Pressure toler-
ances
Pressure tolerance range for HyLOG Fleet 24015F
During refuelling, the pressure tolerance
range as specified in the following standard
must be observed: SAE J2601:DEC2016
8.3.2.
Refuelling pro-
cess
Press the "OFF" button to shut down the fuel cell and place it in the safe state
Open fuel filler flap
Connect the condensate drain
Connect the filler coupling of the hydrogen refuelling system to the filler connection in
accordance with the refuelling system manufacturer's instructions
Carry out the refuelling process in accordance with the instructions of the manufactur-
er of the hydrogen refuelling system
Once the hydrogen tank has reached a pressure of 350 bar (5074.55 psi.), the hydro-
gen refuelling system automatically stops the refuelling process
Close fuel filler flap
p=70 bar (1041.91 psi)
t
p
p
p=25 bar
Lower Pressure
Tolerance
Stationary Pressure
Upper Pressure
Tolerance
target
p
0
(362.47 psi)
1
2
3
4
5
6
7