Location Selection
Please note the following criteria when selecting a location for the Fronius
IG Plus:
It should only be installed on a stable, vertical wall
Max. ambient temperatures: -20 °C / +50 °C (-4 °F / +122.00 °F)
For use at altitudes above sea level: up to 2000 m
General Loca-
tion Selection
300 mm
50 mm
200 mm
The air flow direction within the inverter runs from right to left (cold air
intake right, warm air exhaust left).
If the Fronius IG Plus is installed in a switch box (or similar enclosed
area), then forced-air ventilation must be provided to ensure adequate
heat dissipation.
The Fronius IG Plus is designed for installation both indoors and
outdoors.
-
There should be a 200 mm (7.8 in) clearance on both sides of the
Fronius IG Plus for the cool air vents.
-
Maintain a side distance of 300 mm (11.8 in) between individual Froni-
us IG Plus units.