Criteria for the Proper Selection of String Fuses
Criteria for the
Proper Selec-
tion of String
Fuses
The following criteria must be fulfilled for each solar module string when
using fuse protection:
-
I
N
> 1.5 x I
SC
-
I
N
< 2.00 x I
SC
-
U
N
>/= 600 V DC
-
Fuse dimensions: Diameter 10.3 x 35 - 38 mm
I
N
Nominal current rating of fuse
I
SC
also STC, short circuit current for standard test conditions according
to solar module datasheet
U
N
Nominal voltage rating of fuse
Effects of
using underra-
ted fuses
In underrated fuses, the nominal current value is less than the short circuit
current of the solar module.
Effect:
The fuse may trip in intensive lighting conditions.
Fuse Recom-
mendations -
Application
Example
NOTE
Only select fuses suitable for a voltage of 600 V DC.
e.g.: Maximum short circuit current (I
SC
) of the solar module = 5.75 A
According to the criteria for selecting the correct fuse, the fuse must have
a nominal current greater than 1.5 times the short circuit current:
5.75 A x 1.5 = 8.625 A
The fuse that should be selected according to the ‘Fuses’ table: KLK D 9
with 9.0 A and 600 V AC / DC
General
The use of string fuses in the inverter also adds fuse protection to the
solar modules.
A crucial factor for the fuse protection of solar modules is the maximum
short circuit current (I
SC
or STC) of the respective solar module.
Содержание Fronius IG Plus 100
Страница 2: ......
Страница 4: ...ud_fr_st_et_01382 012008...
Страница 14: ...6...
Страница 15: ...7 General Information...
Страница 16: ...8...
Страница 20: ...12...
Страница 21: ...13 Installation and Startup...
Страница 22: ...14...
Страница 71: ...63 Closing Fronius IG Plus Closing Froni us IG Plus 1 1 4 2 7 3 5 6...
Страница 77: ...69 Operation...
Страница 78: ...70...
Страница 118: ...110...
Страница 119: ...111 Troubleshooting and Maintenance...
Страница 120: ...112...
Страница 141: ...133 Appendix...
Страница 142: ...134...
Страница 152: ...144...
Страница 155: ......