![Fronius Datamanager 2.0 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/fronius/datamanager-2-0/datamanager-2-0_operating-instructions-manual_2339091026.webp)
No
.
Function
(1
3)
External power supply connection
For connecting an external power supply when the power supply within
Fronius Solar Net is insufficient (e.g., when too many DATCOM components
are installed in Fronius Solar Net).
IMPORTANT!
The external power supply unit for the Fronius Datamanager
Box 2.0 must be securely disconnected from components supplying grid
voltage (SELV or Class 2 for USA/Canada).
The output power of the power supply unit may not exceed a max. of 15 VA/
1.25 A.
If the power supply is sufficient, the Supply LED (4) lights up green.
For an external power supply, use only the Fronius power supply unit!
For the Fronius Datamanager Box 2.0 only!
Schematic Con-
nection of I/Os
Supply via the Fronius Datamanager 2.0 plug-in card:
(1)
115 - 230 V AC
12 V DC
10,7 / 12,8 V DC
(2)
300 mA
(3)
D-
-
-
D+
+
+
0
2
5
7
8
9
3
4
6
1
(1)
Power supply
(for Fronius Datamanager 2.0 with Fronius Com Card function only)
(2)
Current limit
(3)
Solar Net IN connection socket
115–230 V AC:
Fronius IG, Fronius IG Plus, Fronius IG Plus V, Fronius IG Plus A, Fronius CL, Fronius
CL USA, Fronius IG 300 - 500
12.8 V DC:
Fronius Galvo, Fronius Symo, Fronius Primo
Supply via external power supply:
26
Содержание Datamanager 2.0
Страница 2: ......
Страница 6: ...6 ...
Страница 7: ...General information 7 ...
Страница 8: ...8 ...
Страница 30: ...30 ...
Страница 31: ...Installing Fronius Datamanager 2 0 31 ...
Страница 32: ...32 ...
Страница 34: ...The next slot must be kept free Never remove an existing ENS plug in card ENS Datamanager 34 ...
Страница 49: ...Establishing a Connection to Froni us Datamanager 2 0 49 ...
Страница 50: ...50 ...
Страница 53: ...Current Data Services and Settings on Fronius Datamanager 2 0 53 ...
Страница 54: ...54 ...
Страница 86: ...86 ...
Страница 87: ...87 EN US ...
Страница 88: ... ...