No
.
Function
A
Specified IP address and opening the WLAN access point
The Fronius Datamanager 2.0 uses fixed IP address 169.254.0.180 for a dir-
ect connection to a PC via LAN.
If the IP switch is set to position A, an access point for a direct WLAN con-
nection to the Fronius Datamanager 2.0 is also opened.
Access data for this access point:
Network name: FRONIUS_240.XXXXXX
Key: 12345678
The Fronius Datamanager 2.0 can be accessed:
-
via DNS name "http://datamanager"
-
via IP address 169.254.0.180 for the LAN interface
-
via IP address 192.168.250.181 for the WLAN access point
B
Assigned IP address:
The Fronius Datamanager 2.0 works with an assigned IP address dynamic
host configuration protocol (DHCP)
The IP address can be set on the Fronius Datamanager 2.0 website.
In the case of the Fronius Datamanager 2.0 plug-in cards, the IP switch is
located underneath the LEDs and is separate in the case of the Fronius
Datamanager Box 2.0.
(2)
WLAN LED
-
Flashes green: the Fronius Datamanager 2.0 is in service mode
(IP switch on the Fronius Datamanager 2.0 plug-in card is set to posi-
tion A or service mode was activated via the inverter display, the WLAN
access point is opened)
-
Lights up green: there is an existing WLAN connection
-
Flashes green/red alternately: the length of time for which the WLAN ac-
cess point is open after activation (1 hour) has been exceeded
-
Lights up red: there is no existing WLAN connection
-
Flashes red: faulty WLAN connection
-
Does not light up: the Fronius Datamanager 2.0 is in secondary mode
(3)
Solar.web LED connection
-
Lights up green: there is an existing connection to Fronius Solar.web
-
Lights up red: there is no existing connection to Fronius Solar.web, but
one is required
-
Does not light up: no connection to Fronius Solar.web is required
(4)
Power supply LED
-
Lights up green: sufficient power supply from Fronius Solar Net; the
Fronius Datamanager 2.0 is ready for operation.
-
Does not light up: no power or insufficient power supply from Fronius
Solar Net - an external power supply is required
or the
Fronius Datamanager 2.0 is in secondary mode
-
Flashes red: during an update process
IMPORTANT!
Do not interrupt the power supply during an update pro-
cess.
-
Lights up red: update process failed
23
EN-US
Содержание Datamanager 2.0
Страница 2: ......
Страница 6: ...6 ...
Страница 7: ...General information 7 ...
Страница 8: ...8 ...
Страница 30: ...30 ...
Страница 31: ...Installing Fronius Datamanager 2 0 31 ...
Страница 32: ...32 ...
Страница 34: ...The next slot must be kept free Never remove an existing ENS plug in card ENS Datamanager 34 ...
Страница 49: ...Establishing a Connection to Froni us Datamanager 2 0 49 ...
Страница 50: ...50 ...
Страница 53: ...Current Data Services and Settings on Fronius Datamanager 2 0 53 ...
Страница 54: ...54 ...
Страница 86: ...86 ...
Страница 87: ...87 EN US ...
Страница 88: ... ...