Calculating the data volume
General
When operating Fronius Datamanager 2.0, data is generated and needs to be transmit-
ted online.
In order to select a suitable internet connection it is necessary to calculate the data
volume.
The following data volume calculation provides an overview of the amount of data gener-
ated when operating Fronius Datamanager 2.0.
Firmware Ver-
sions for Calcu-
lating the Data
Volume
The data volume calculation is based on Fronius Datamanager 2.0 firmware versions V
3.3.x-x and lower.
Higher firmware versions can cause a higher data volume due to their increased func-
tional range.
Calculating data
volumes
The data volume calculation depends on which Fronius Datamanager 2.0 functions are
activated.
Function
Data volume
Make real-time data
available in Fronius Sol-
ar.web
Once
1)
150 bytes
32 KB/h
View real-time data in
Fronius Solar.web
Current overall view
per sensor card/sensor box
42 KB/h
+ 300 KB/h
Current comparison view
per inverter
13 KB/h
+ 4 KB/h
Start page
0 KB/h
System comparison view
0 KB/h
Send archived data/
logging data to Froni-
us Solar.web
(Memory sectors per day
2)
x 4 KB) + 8 KB
Transmission time
3)
600 bytes/min
Send service messages
or errors
For daily sending
per service message or error
1 KB/day
+ 300 bytes
For immediate sending
per service message or error
1 KB
1
)
Only after a restart or if the internet connection has been disconnected
2
)
Calculation of memory sectors per day according to chapter "Calculating memory capa-
city" on page
3
)
Depending on the quality of the internet connection
IMPORTANT!
Since the values listed in the table are "rough data" for Fronius Dataman-
ager 2.0 and the provider's bill may show discrepancies as a result of the various meth-
ods of calculating the transfer volume, the total value should be increased by 10–20%.
16
Содержание Datamanager 2.0
Страница 2: ......
Страница 6: ...6 ...
Страница 7: ...General information 7 ...
Страница 8: ...8 ...
Страница 30: ...30 ...
Страница 31: ...Installing Fronius Datamanager 2 0 31 ...
Страница 32: ...32 ...
Страница 34: ...The next slot must be kept free Never remove an existing ENS plug in card ENS Datamanager 34 ...
Страница 49: ...Establishing a Connection to Froni us Datamanager 2 0 49 ...
Страница 50: ...50 ...
Страница 53: ...Current Data Services and Settings on Fronius Datamanager 2 0 53 ...
Страница 54: ...54 ...
Страница 86: ...86 ...
Страница 87: ...87 EN US ...
Страница 88: ... ...