Boiler Maintenance
Cleaning and Maintenance
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen
Page 15
Tel. +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 [email protected]
www.froeling.com
Edition: 23.03.2005
4
4 Boiler
maintenance
IMPORTANT
Maintenance when the boiler is hot.
Burn hazard from hot parts or in extreme cases, poisonous smoke
inhalation due to smouldering wood!
Before starting maintenance on the boiler:
U
Allow the fuel to burn completely
U
Allow boiler to cool off and shut down
IMPORTANT
Working on electrical components.
Hazard - Risk of electric shock
U
Work on electrical components must only be carried out by authorised skilled electricians.
4.1
Inspection, Cleaning and Maintenance
Recommended:
When cleaning, use an ash vacuum.
4.1.1 Daily
Maintenance
Cleaning the heat-exchanger pipes (with heat-exchanger technology)
U
Activate the lever of the cleaning system several times
before the heating-up process (5-10 times up and down)
4.1.2 Weekly
Maintenance
Removing the ash
U
Open the insulating door and the central pre-heating
chamber door
U
Using the ash scraper, scrape the ash located above the
combustion chamber into the combustion chamber
U
Open the combustion chamber door
U
Remove the ash using the rounded ash shovel
U
Shovel the ash into the container intended to receive it
Fire-proof container with a cover!