![Froling FHG Turbo 3000 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/froling/fhg-turbo-3000/fhg-turbo-3000_operating-instructions-manual_2338696011.webp)
Operating the System
Initial start-up
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen
Page 11
Tel. +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 [email protected]
www.froeling.com
Edition: 23.03.2005
3
3
Operating the system
3.1 Initial
start-up
NOTE
Conduct the initial start-up with an authorized installer or Fröling’s customer
service department!
NOTE
Escaping condensation during the initial heat-up phase does not indicate a
malfunction.
´
Clean up later using a cleaning rag
IMPORTANT
Heating up the boiler too rapidly during initial start-up.
Equipment damage hazard.
If the output during the heating-up process is too great, the combustion chamber may become
damaged due to drying too rapidly!
Drying fissures, on the other hand, are normal and do not indicate a malfunction!
U
Load the boiler with a small amount of waste-wood (max. 10-20% of the fuel loading
chamber)
U
Ignite it and allow it to burn up with the central pre-heating chamber door open
U
Repeat the procedure several times until the combustion chamber is dried out
3.1.1
Checking the heating system
Observe local regulations, but at the very least:
U
Check that there is sufficient water in the heating system.
À
See page 16, Checking the system pressure
U
Check to see whether the heating system has been completely vented.
U
Check that all the safety devices are correctly fitted and are fully efficient.
À
See 2.3 Safety devices
U
Check that there is sufficient ventilation and venting.
À
See 2.2.3 Ventilating the Boiler Room