![Froling FHG Turbo 3000 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/froling/fhg-turbo-3000/fhg-turbo-3000_operating-instructions-manual_2338696014.webp)
Operating the System
Heating up the boiler
Page 14
a
B 003 04 05
a
3
Operating without a storage tank
Feed based on output
Only replenish the fuel if energy is needed!
If too much fuel is loaded:
´
The boiler drops below its minimum output limit and switches over to so-called low-
temperature operation (fan switches off)
During low-temperature operation, the efficiency drops, the emissions increase and the
boiler tars up (pitch formation!)
3.2.6
Switching off the system
IMPORTANT! Only switch off when the boiler has
cooled down.
S
witch off the main switch 9 at the control system
´
The controller is switched off.
´
All the system components are powered down.
9