Operating the System
Heating up the boiler
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen
Page 13
Tel. +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 [email protected]
www.froeling.com
Edition: 23.03.2005
3
Lambdatronic S3100
U
Set the INDUCED DRAUGHT FAN selector switch
7.4
or
8.1
to “Automatic”
Digitronic S3100
U
Leave the pre-heating chamber door open for
approximately 5 minutes
´
A bed of embers forms
U
Close the pre-heating chamber door and the insulating
door
The flue gas temperature must be > 130°C!
3.2.4
Controlling the boiler
Necessary control steps. Displaying or modifying parameters:
À
See the operating instructions for the “Digitronic S 3100” or “Lambdatronic S 3100”
3.2.5
Refilling the fuel
U
Open the central pre-heating chamber door and check
the fuel
If the fuel in the boiler has burned up:
U
Open the upper fuel loading door and refill the chamber
with fuel
Operating with a storage tank
The reloading intervals should depend exclusively on the storage tank!
If the temperature of the storage tank above has dropped to a certain temperature (floor
heating: ca. 30-40 °C, radiator heating: ca. 50 °C), reload fuel.
The amount of fuel should be measured so as to ensure that the storage tank is continuously
warmed to the maximum storage temperature (max. 80-90 °C).
The amount to reload also depends on the type of fuel!
8.1
7.4