![Froling FHG 20 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/froling/fhg-20/fhg-20_installation-manual_2338695030.webp)
Boiler Installation
Boiler assembly
Page 30
M1060008_US
v
3
Attach the left- and right-hand
cover plates using self-tapping
screws
Push the actuator onto the
pneumatic rod and fasten in
position
Label the cables for the actuators
using the stickers provided
Upper actuator = primary air
Lower actuator = secondary air
Push on the cable cover and fix in
position using self-tapping screws
3.5.6
Fitting the induced draught fan
Fit the induced draught fan on the
rear side of the boiler as shown
Caution: Do not overstress the
flange
Attach the left- and right-hand cover
plates using self-tapping screws
Содержание FHG 20