Boiler Installation
Boiler Assembly
Froling GmbH, Industriestrasse 12, A-4710 Grieskirchen, Austria
Page 23
www.froling.com
M1060008_US
3
3.5
Installing the FHG
3.5.1
Installing the flue gas pipe nozzle
Place the ceramic fiber gasket in
position
Position the flue gas pipe nozzle and
attach it using the pre-installed
spacer washers and nuts
Caution: ½" sleeve must point to the
left as viewed from the rear of the
boiler.
3.5.2
Install the pneumatic rods for the primary and secondary air
For both pneumatic rods:
Remove the split pin opposite the spring and pull off one of the air
flaps.
Right-hand actuators
The hex head bolt (1) in the above picture must be used on the other
side.
Unscrew the stop screws on the right-hand side of the boiler far
enough to allow the air flap to make contact with the thread.
Insert the pneumatic rod at the left-hand side of the boiler
The flap with the spring (2) must be at the left-hand air duct.
Position the flaps on the opposite side
Caution: Install the flaps in the same
position.
Secure the flaps with the split pins
2
1
1