116
Problem
Solution
Replace the batteries in the outside sensor array.
With the sensor array and console 10 feet away from
each other, remove AC power from the display
console and wait 10 seconds. Re-connect power.
Temperature sensor reads
too high in the day time.
Make certain that the sensor array is not too close to
heat generating sources or strictures, such as
buildings, pavement, walls or air conditioning units.
Use the calibration feature to offset installation issues
related to radiant heat sources. Reference 6.6.
Absolute pressure does not
agree with official reporting
station
You may be viewing the relative pressure, not the
absolute pressure.
Select the absolute pressure. Make sure you properly
calibrate the sensor to an official local weather station.
Reference Section 6.6 for details.
Rain gauge reports rain
when it is not raining
An unstable mounting solution (sway in the mounting
pole) may result in the tipping bucket incorrectly
incrementing rainfall. Make sure you have a stable,
level mounting solution.
Data not reporting to
Wunderground.com
1. Confirm your password is correct. It is the
password you registered on
Wunderground.com. Your
Wunderground.com password cannot begin
with a non-alphanumeric character (a
limitation of Wundeground.com, not the
station). Example, $oewkrf is not a valid
password, but oewkrf$ is valid.