F
riStam
P
umPS
18
S
haFt
anD
/
or
b
earing
r
epLacement
Begin all pump maintenance by disconnecting the energy source to the pump.
Observe all lock out/tag out procedures as outlined by ANSI Z244.1-1982 and OSHA
1910.147 to prevent accidental start-up and injury.
t
ooLS
requireD
For
ShaFt
anD
/
or
bearing
repLacement
15
58 L & S
75 L & S
• 10 mm wrench
• 10 mm wrench
• 10 mm wrench
• 5 mm Allen wrench
• 5 mm Allen wrench
• 5 mm Allen wrench
• 10 mm tube for bearings
• 15 - 17 mm tube for
bearings
100 L & S
130 L & S
• 17 mm wrench
• 17 mm wrench
• 6 mm Allen wrench
• 8 mm Allen wrench
• KM12 spanner wrench
Tools for all models:
• Spanner wrench
• Wooden dowel
• Feeler gauges
• Soft-faced hammer
• Flat blade screwdriver
• Indicating torque wrench
• Mild steel rod
• Bearing heater
• Arbor press (beneficial)
g
earbox
D
iSaSSembLy
Remove the oil drain plug and drain the oil.
Remove the coupling key from the drive
shaft.
FL2 15 & 58
: remove guards.
Remove the rear cover bolts from the rear
cover.
Pull the rear cover off the drive shaft exten-
sion. If the cover sticks use a soft-faced
hammer to loosen it.
Remove the rear cover oil seal from the
rear cover and discard.
Remove the rear cover o-ring from the rear
cover and discard.
Straighten the locking tab of the bearing
lock washer. Reinstall the rotors on the
drive and idle shafts. Lock the rotor with a
wood dowel. Remove the lock nut and lock
nut washer from the drive shaft and idle
shaft.
!
Figure 20
for models
FL2 55-100